ALARM MEMORY
When disarming the alarm, if five turn signal flashes and five beep signals
occur, it is possible to identify the cause generating the alarm condition.
To do this, turn the ignition key to “ON” position and look at the vehicle installed
LED.
The LED will be blink, shown the last alarm condition.
The cause of the alarm will indicate for 5 times, and this indication can be
interrupted by turning the ignition key to “OFF” position.
The possible alarm signalling are indicated in the table below.
LED SIGNAL CAUSE OF THE ALARM
NUMBERS OF
ALARM CYCLES
5
5
Infinite
5
5
5
Volumetric sensor
Doors/boot switches
Positive under key (+15/54)
Absorption sensor
External magnetic contact
Bonnet switch and
volumetric sensors
LED ON (400mS)LED OFF (2 seconds)
NEUTRAL TIME
SYSTEM ARMED AFTER NEUTRAL TIME
EVENTS THAT CAN GENERATE AN ALARM CONDITION
NOTE:
ALARM DISARMING
At the end of each alarm cycle there is a neutral time period, lasting up to
approx. 5”, during which there will be no reaction to the causes of alarm. During
the neutral time between successive alarms, the LED will emit a continuous
light. Normal flashing will be resumed at the end of the neutral time.
At the end of the neutral time (approx. 45”), the security system is completely
armed and ready to intervene in cases of attempted theft or sabotage.
Completely armed status is indicated by the flashing of the LED, which will wok
according to the following timing scheme in order to minimise power
consumption:
LED ON : 200mS
LED OFF : 2”
System wire cutting by means of the self-powered siren
Attempt to start the engine.
Power drained. This function is active only if enabled in the accessory
function programming phase and can be used only in countries where the
law does not prohibit the use of this sensor.
Attempt to open the doors.
Attempt to open boot.
Attempt to open engine bonnet.
Intrusion detected by internal ultrasound volume sensor.
Intrusion detected by external sensors (option,also by radio).
Panic alarm by pressing key no. 2 on the remote (this function is active
only if enabled in the accessory function programming phase and it can be
used only in countries where the law permits this type of alarm activation
not available in product version for the dutch market).
In order to filter noise and/or undesired signals, the POSITIVE UNDER
KEY, DOORS and BOOT PUSH-BUTTON inputs have a DEBOUNCE time of
200mS. Therefore these inputs will cause the generation of an alarm cycle only
if the signals coming in last longer than 200mS.
For every input and every arming cycle, the alarm causes are limited to 10
cycles of 30 seconds each. The only alarm causes having no limits, is starting
attempt (positive under key +15/54).
The alarm system can be deactivated by pressing key 1 on the remote, by
inserting the electronic key into the appropriate receptacle or by means of the
emergency PIN CODE procedure.
Disarming is indicated by three turn signal flashes and three acoustic signals.
If an alarm condition has occurred, it will be signalled by five turn signal flashes
and five acoustic signals (if these functions have not been excluded in
programming stage).
See next paragraph for all signalling.
!
!
!
!
!
!
!
!
!
NOTE:
SUPPLEMENTARY SIREN OPERATION
ORIGINAL HORN OPERATION
NOTE:
the cause of alar of CUT WIRE does not enabled the alarm memory
because it is managed by the external self-powered sirene.
Continuous audible signal for the entire duration of the alarm signal cycle.
Intermittent sound 2” ON 2” OFF for the entire duration of the alarm signal
cycle.
If the user has cut out the siren, the alarm condition will be indicated solely by
the flashing of the turn indicators for a maximum time period of 30”.
While the alarm signal is given out, the LED will emit a continuous light.
You can cut off the alarm cycle without deactivating the system, by pressing
key no. 2 on the remote. As you do so, the audible/visible alarm signals will be
immediately cut off, and the system will switch to the condition of NEUTRAL
TIME BETWEEN SUCCESSIVEALARMS.
To minimise acoustic pollution, the DOORS PUSHBUTTON, BOOT
PUSHBUTTON, BONNET PUSHBUTTON, ELECTRICAL INPUT SENSOR,
INTERNAL VOLUME SENSOR and EXTERNAL SENSORS inputs are
subject to a limitation of up to five alarm cycles per system activation period.
The count is reset upon the next deactivation of the alarm system or if an alarm
for POSITIVE POLE UNDER KEY intervenes during the same activation
cycle.
PAG . 5
PAG . 4
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gemini 7590T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gemini 7590T in the language / languages: English as an attachment in your email.

The manual is 0,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info