17767
40
Zoom out
Zoom in
Previous page
1/88
Next page
Manufactured for: General Electric Company, Louisville, KY 40225
Performance Data Sheet
SmartWater Filtration System
GWF / HWF Cartridge
This system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter USEPA Influent Effluent % Reduction Min. Required
MCL Challenge Concentration Average Maximum Average Minimum Reduction
Chlorine 2.0 mg/L + 10% 0.02 ppm 0.05 ppm 98.90% 97.37% > 50%
T & O
Particulate** at least 10,000 particles/mL 3,978 7,800 98.00% 96.10% > 85%
Standard No. 53: Health Effects
Parameter USEPA Influent Effluent % Reduction Min. Required
MCL Challenge Concentration Average Maximum Average Minimum Reduction
Turbidity 1 NTU*** 11 + 1 NTU*** 0.07 NTU 0.1 NTU 99.71% 99.59% 0.5 NTU
Cysts
99.95% Reduction
Minimum 50,000 L 26 55 99.97% 99.95% > 99.95%
Lead at pH 6.5 15 ppb 0.15 mg/L + 10% 1 ppb 1 ppb 99.37% 99.37% 0.010 mg/L
Lead at pH 8.5 15 ppb 0.15 mg/L + 10% 1.8 ppb 4.3 ppb 98.8% 97.13% 0.010 mg/L
Lindane
0.0002 ppm
0.002 mg/L + 10%
0.00005 ppm 0.00005 ppm
91.93% 91.93% 0.0002 mg/L
Atrazine
0.003 ppm
0.009 mg/L + 10% 0.002 ppm 0.003 ppm 76.19% 64.28% 0.003 mg/L
2,4-D
0.100 ppm
0.210 mg/L + 10% 0.042 ppm 0.090 ppm 84.89% 67.63% 0.07 mg/L
Asbestos
99%
10
7
to 10
8
fibers/L; 0.32 MFL/ml 1.2 MFL/ml 99.95% 99.82% 99%
fibers greater than
10 micrometers in length
* Tested using a flow rate of 0.5 gpm; pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 20° ± 2.5°C
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity units
Operating Specifications
Capacity: certified for up to 500 gallons (1135 l); up to twelve months for all models
Pressure requirement: 40–120 psi (2.8–8.2 bar), non-shock
Temperature: 33–100ºF (0.6–38ºC)
Flow rate: 0.5 gpm (1.9 lpm)
General Installation/Operation/Maintenance Requirements
Flush new cartridge at full flow for 3 minutes to purge out trapped air.
Replace cartridge when flow becomes too slow.
Special Notices
Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter
cartridges.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or
after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your
water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems
must be installed and operated in accordance with manufacturer’s recommended procedures and guidelines.
NSF
®
System Tested and Certified by NSF International against ANSI/NSF Standard 42 & 53 for
the reduction of:
Standard No. 42: Aesthetic Effects
Chemical Unit
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction, Class I
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead and Atrazine Reduction
Lindane and 2,4-D Reduction
Mechanical Filtration Unit
Turbidity Reduction
Cyst and Asbestos Reduction
40
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for GE PSB48LSRBV at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of GE PSB48LSRBV in the language / languages: English, French as an attachment in your email.

The manual is 1,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info