Disconnect the 2 x 8mm and 1 x 4mm gas pipe ttings at the back
of the gas valve (A).
Disconnect the thermocouple (B).
AA
B
C
Disconnect the ignition lead from the gas valve (C).
Remove the cover.
Undo the 2 screws securing the gas valve to the appliance and
remove the valve.
Replace in reverse order.
Check all joints for gas leaks and check operation of the
thermocouple and ignition lead.
MAGNETIC SAFETY VALVE
Turn the gas supply off at the isolation device.
Remove the gas valve.
Undo the magnetic valve-retaining nut from the back of the control
valve.
Gently tap out the magnetic valve and replace with a new unit.
Replace the retaining nut and tighten.
Reassemble the interrupter block and leads and secure the
thermocouple connection in the rear of the gas control. (Do not
overtighten).
Turn the gas supply on and check the entire pipework and valve
joints for any leaks.
MAIN INJECTOR
To remove the main injector turn off the gas supply at the isolation
device.
Remove the main burner.
Undo the compression nuts from the feed pipe and the gas
valve under the appliance.
Working from inside the rebox remove the lock nut from the
injector.
Extract the injector with the feed pipe from beneath the appliance.
Holding the injector with a spanner:
Undo the feed pipe. Note the orientation of the Injector.
Re-assemble in reverse order.
Turn on the gas supply and check for leaks.
GLASS SIDE PANELS -
MIDI T MODELS ONLY
To service the glass side panels, rst remove the back panel and
the side trims.
Undo the four screws securing the front bracket and remove.
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Vogue Range Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Vogue Range Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 7.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info