813426
5
Zoom out
Zoom in
Previous page
1/48
Next page
5
All Models
The valve has two controls.
1. The right-hand knob controls the pilot ignition.
2. The left-hand knob controls the main burner.
Refer to separate instructions if your appliance is upgraded to
include battery remote control. The instructions below apply
whether or not you have the remote upgrade.
Lighting the Pilot
To start the left-hand and right-hand control knobs must both point
to off ( ):
Press in the right-hand control knob and rotate anti-clockwise until
a click is heard. Continue to press in. The knob points to the pilot (
).
The pilot is lit.
Keep the knob depressed for 10 seconds before releasing. The
pilot remains lit.
Repeat the above steps if the pilot does not stay lit.
NOTE: If the pilot goes out, the Interlock system prevents you
lighting again for a short period.
If, after repeating the above steps the pilot does not light, contact
your Retailer or Installer.
Turn the right-hand knob to the left to main burner
setting ( ).
Adjusting the Flame height
You can now adjust the ame height and temperature using the left-
hand control knob.
Turn the left-hand knob anti-clockwise to increase the
ame height.
Turn clockwise to decrease the height.
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT
OR BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.
TURNING OFF THE APPLIANCE
To turn the main burner off turn the left-hand knob until it points to
off ( ). Just the pilot remains lit.
Press in and turn the right-hand knob until it points to off
( ). The pilot goes out.
UPGRADING THE APPLIANCE
The appliance is tted with a control valve that can easily be
upgraded to battery powered remote control.
There are two versions of this control which can be obtained
through your local Gazco retailer.
There is no requirement for this upgrade to be carried out by an
approved GasSafe engineer. However Gazco recommend that this
task is undertaken by a suitably competent person.
This upgrade can be tted before or after installation but if
side clearances are limited then it will be easier to upgrade the
appliance before installation. Full instructions are included with the
kit.
If the appliance is left unattended for long periods of
time (e.g. vacation), it is recommended to place the
control valve in the Off or Pilot posiiton.
Take care when leaving the appliance unattended,
in exceptional circumstances sound waves from
sources other than the transmitter can cause
changes in the ame height adjustment.
DO NOT install two or more appliances using
upgradeable controls in the same room, interference
between the remote control frequencies can occur.
STANDARD REMOTE CONTROL
(PART NUMBER 8455)
This remote control can control the gas appliance after
the pilot has been lit. It can turn the main burner on and regulate it
from low through to high and back again.
It can turn the main burner off leaving the pilot burning.
THERMOSTATIC AND TIMER REMOTE
CONTROL (PART NUMBER 8456)
This remote control can control the gas appliance after the pilot has
been lit.
MANUAL MODE
Can be used to turn the main burner on and manually regulate it from
low through to high and back again. It can also be used to turn the
main burner off leaving the pilot burning.
AUTO MODE
Will automatically regulate the room to a pre-set temperature.
TIMER MODE
Will turn the appliance on and off according to a pre-set programme
and automatically regulate the room temperature during the two on
periods.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Vogue Range Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Vogue Range Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 7.15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info