813417
11
Zoom out
Zoom in
Previous page
1/36
Next page
11
Installation Instructions
1. Flue & Chimney Requirements
WHEN INSTALLING A FLUE SYSTEM PLEASE REFER
TO THE MANUFACTURER’S INSTRUCTIONS.
The European chimney standards now describe chimneys
and ues by their temperature, pressure and resistance
to corrosion, condensation and re. To identify the correct
ue system, the minimum ue specication is shown in the
Technical Specication. Existing chimneys are not covered
by this system.
The ue must be installed in accordance with all local and
national regulations and the current rules in force:
1.1 A exible liner must be continuous from the appliance spigot
to the roof terminal.
1.2 The minimum effective height of the ue must be 3m (10').
1.3 The ue must be free from any obstruction.
1.4 Any damper plates must be removed or secured in the fully
open position and no restrictor plates tted.
1.5 The chimney should be swept immediately before installing
the appliance, but it need not be swept if you can see the
chimney is clean and free from obstruction throughout.
2. Flue Options
Top Exit only - Twin Wall Rigid 127mm (5”)
A range of Vitreous Enamel Gloss Black ue pipe is available
to compliment the Vision. Please contact your Gazco retailer
for further information.
3. Gas Supply
This appliance is intended for use on a gas installation
with a governed meter.
3.1 Make sure local distribution conditions (identication of
the type of gas and pressure) and the adjustment of the
appliance are compatible before installation.
3.2 Ensure the gas supply delivers the required amount of gas
and is in accordance with the rules in force.
3.3 Soft copper tubing can be used on the installation and soft
soldered joints outside the appliance and below the rebed.
3.4 A factory tted isolation device is part of the inlet connection;
no further isolation device is required.
3.5 All supply gas pipes must be purged of any debris that may
have entered prior to connection to the appliance.
3.6 The gas supply must be installed in a way that does not
restrict the removal of the appliance for servicing and
inspection.
4. Ventilation
IMPORTANT: Ensure any national ventilation
requirements are taken into account during installation
of the appliance.
UK ONLY:
The Vision has a nominal input not exceeding 7.0kW
and does not normally require any additional permanent
ventilation.
If however, spillage is detected when commissioning the
appliance, there may be insufcient natural ventilation and
additional ventilation may be required.
FOR THE REPUBLIC OF IRELAND REFER TO THE
RULES IN FORCE FOR VENTILATION REQUIREMENTS.
5. Appliance Location
5.1 This appliance has been designed to stand on either a
hearth or an optional bench:
Code Bench Width
RVACLB100B Riva Bench Low 1000mm
RVACB100B Riva Bench 1000mm
RVACLB120B Riva Bench Low 1200mm
RVACB120B Riva Bench 1200mm
RVACLB140B Riva Bench Low 1400mm
RVACB140B Riva Bench 1400mm
5.2 To install the bench:
Follow Section 1, Installation - All Models in the installation
guide (PM205) supplied with the bench kit.
5.3 To secure the appliance to the bench:
You must consider where you place the appliance on the
bench before using the template, see Diagram 1.
1
Site Requirements
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Vision Large MK2 Series Conventional Flue Instructions at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Vision Large MK2 Series Conventional Flue Instructions in the language / languages: English as an attachment in your email.

The manual is 4.35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info