2C. Top Flue Vertical Kit
(8524/8524AN)
2.3 Vertical from the top of the appliance, see Diagram 1C.
A minimum vertical rise 3m (9’10") to a maximum 10m
(32’10").
The basic kit comprises:
2 x 1m lengths
1 x 1m terminal length
1 x 52mm restrictor
1 x 47mm restrictor
1 x 60mm restrictor
1 x 70mm restrictor
Extra lengths may be added from the table, see Section 3.
1C
2D. Top Flue Vertical Offset
Kit (8530/8530AN)
2.4 Used with kit 8524. A minimum rise of 500mm (19½) is
required to the first bend, see Diagram 1C.
Installation Instructions
Site Requirements
3. Optional Extra Flue Lengths and Bends
All flue components are 150mm diameter (6")
Nominal
Length
Actual
Length
Stainless
Finish
Anthracite
Finish
200mm 140mm 8527 8527AN
500mm 440mm 8528 8528AN
1000mm 940mm 8529 8529AN
45° Bend N/A 8507 8507AN
90° Bend N/A 8508 8508AN
NOTE: Carefully consider:
a) Terminal positions
b) Flue supports
c) Weatherproofing
d) Fire precautions
For all the above options, you must conform to local
and national codes of practice .
4. Gas Supply
THIS APPLIANCE IS INTENDED FOR USE ON A GAS
INSTALLATION WITH A GOVERNED METER.
4.1 Before installation, ensure that the local distribution
conditions (identification of the type of gas and pressure)
and the adjustment of the appliance are compatible.
4.2 Ensure the gas supply delivers the required amount of gas
and is in accordance with the rules in force.
4.3 Soft copper tubing can be used on the installation and soft
soldered joints outside the appliance and below the firebed.
4.4 A factory fitted isolation device is part of the inlet connection;
no further isolation device is required.
4.5 All supply gas pipes must be purged of any debris that may
have entered prior to connection to the appliance.
4.6 The gas supply enters through the rear of the LEFT-HAND
side of the outer box:
4.7 The gas supply must be installed in a way that does not
restrict the removal of the appliance for servicing and
inspection.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Vision Large MK2 Series Balanced Flue Instructions at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Vision Large MK2 Series Balanced Flue Instructions in the language / languages: English as an attachment in your email.

The manual is 4.65 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info