5.2 Remove the 8 screws holding the glass frame, see Diagram 3.
Take care to support the glass when removing the screws.
3
5.3 Remove the glass frame and place carefully to one side.
5.4 Carefully remove the ceramic fuel bed components and set
aside. Protect the floor coverings and follow the advice
given in Section 6.
5.5 The logs should not require cleaning. Do not use a vacuum
cleaner or brush to clean the logs. Any large pieces of
debris may be removed by hand.
5.6 Ensure any debris is removed from the burner ports.
5.7 Replace the ceramics, see Section 6.
5.8 Ensure that the rope seal on the back of the glass frame is
intact. Replace the glass frame and tighten the 8 screws,
see Diagram 3.
5.9 Offer the decorative steel trim to the opening, inserting the 2
tags on the bottom of the trim behind the bottom panel. Lift
the top of the trim up and hook the lugs on the back of the
trim over the top of the glass frame, see Diagram 4.
4
NEVER OPERATE THE APPLIANCE WHEN THE GLASS
FRAME IS REMOVED, OR THE GLASS IS BROKEN.
5.10 Replace ALL of the securing screws ensuring that a screw is
present in all fixing slots.
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE BE USED IF ANY OF THE FRAME
RETAINING SCREWS ARE LOOSE OR MISSING.
User Instructions
5.11 Use a damp cloth to clean the outer casing of the appliance.
6. Arrangement of Fuel Bed
Advice on handling and disposal
of fire ceramics
The fuel effect and side panels in this appliance
are made from Refractory Ceramic Fibre (RCF), a
material which is commonly used for this
application.
Protective clothing is not required when
handling these articles, but we recommend you
follow normal hygiene rules of not smoking,
eating or drinking in the work area and always
wash your hands before eating or drinking.
To ensure that the release of RCF fibres are kept
to a minimum, during installation and servicing a
HEPA filtered vacuum is recommended to
remove any dust accumulated in and around the
appliance before and after working on it. When
servicing the appliance it is recommended that
the replaced items are not broken up, but are
sealed within heavy duty polythene bags and
labelled as RCF waste.
RCF waste is classed as stable, non-reactive
hazardous waste and may be disposed of at a
licensed landfill site.
Excessive exposure to these materials may
cause temporary irritation to eyes, skin and
respiratory tract; wash hands thoroughly after
handling the material.
7. Log Layout
7.1 Remove the decorative trim and glass frame, see Section 5.
WARNING: NEVER CLEAN THE APPLIANCE WHILE
IT’S HOT. THE APPLIANCE STAYS HOT FOR A
LONG TIME AFTER SHUTDOWN.
IMPORTANT: THE OUTER PANELLING AND
DECORATIVE TRIM OF THE APPLIANCE ARE MADE
FROM STEEL. TAKE CARE WHEN INSTALLING,
REMOVING AND STORING TO AVOID DAMAGING
THE OUTER CASING, HEARTH OR DOOR.
The fuel bed consists of 5 logs and 2 ash panels. The logs
have letters A,B,C,D and E moulded into them for
identification.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Steel Manhattan Log Conventional at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Steel Manhattan Log Conventional in the language / languages: English as an attachment in your email.

The manual is 2.32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info