FLUE & CHIMNEY REQUIREMENTS
Note: This appliance must only be installed with the ue supplied.
The following: must be adhered to:
The ue must be sited in accordance with BS5440: Part 1 (latest edition).
Fit a guard to protect people from any terminal less than 2 metres above any access such as level ground, a balcony or above a at roof.
All vertical and horizontal ues must be securely xed and re precautions followed in accordance with local and national codes of practice.
Two types of ue terminals are available, horizontal and vertical.
To measure for a horizontal terminal decide on the terminal position.
Measure the height from the top of the appliance to the centre of the required outlet.
For minimum and maximum ue dimensions see relevant sections.
Allow enough room either above or to the side of the appliance to assemble the ue on top.
Assemble a horizontal ue in the following order:
— Vertical section
— 90° elbow
— Horizontal plus terminal
Support the opening of a masonry installation with a lintel.
Only the horizontal terminal section can be reduced in size.
TIMBER FRAMED BUILDINGS
It will be necessary to provide additional clearance when the flue passes through a wall containing any combustible materials so as to prevent
a fire hazard.
The hole through which the flue will pass, must have a steel sleeve which is positioned so that an air gap of at least 25mm is maintained
between the outer surface of the flue, and any part of the sleeve.
For further guidance on the installation of gas appliances in timber framed buildings, contact your local buildings control authority.
GAS SUPPLY
This appliance is intended for use on a gas installation with a governed meter.
Make sure local distribution conditions (identication of the type of gas and pressure) and the adjustment of the appliance are compatible before
installation.
Ensure the gas supply delivers the required amount of gas and is in accordance with the rules in force.
Soft copper tubing can be used on the installation and soft soldered joints outside the appliance.
A factory tted isolation device is part of the inlet connection; no further isolation device is required.
All supply gas pipes must be purged of any debris that may have entered prior to connection to the appliance.
The gas supply must be installed in a way that does not restrict the removal of the appliance for servicing and inspection.
VENTILATION
The installation of this product requires no additional ventilation modications to the building.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Sheraton 5 - Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Sheraton 5 - Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 8.83 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info