PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE
Ensure there is no debris around the pilot assembly,
(e.g. soot etc.) Check for fluff in the pilot aeration hole.
See the Diagram in the Replacing Parts section.
Problem is with the
pipe work or
fittings which lead
to the appliance.
Correct
and retry.
Is thermocouple
connection good
in back of valve?
Replace pilot unit.
Will pilot
stay alight?
Change mag
unit.
Is the pilot flame of the
correct length?,
see Replacing Parts,
Diagram 14.
Are the thermocouple
leads damaged or loose
in the interrupter block?
Change the
pilot unit.
Will pilot
stay alight?
With the pilot
running is the gas
pressure as stated on
the data badge?
With the appliance
running on full is the
gas at
the pressure stated
on the data badge?
Run for 3 mins,
turn off, time interval
until mag unit shuts
with a click. Is this
greater than 7
seconds?
Run for 3 mins, turn
off, time interval until
mag unit shuts with a
click. Is this greater
than 7 seconds?
Tighten the
connection and retry.
No
No
No
No
No
No
Yes
SYSTEM OK
Yes
Yes
Yes
Yes
No
Yes
Yes
No
Light the pilot using either the handset or the touch pad
FLAME FAILURE FUNCTIONAL CHECK 3
IGNITION FUNCTIONAL CHECK 2
NO SPARK
Ensure there is no debris around the pilot assembly,
(e.g. soot etc.) which could short the spark, clean the area.
Consult the users
instructions, retry.
From Ignition Fault
Finding Chart 1
Is the gap between
electrode and
thermocouple 4.0mm?
Has ignition lead
become detached or is
connection poor?
Remove the ignition lead
from electrode. With insulated
pliers. Hold the tip 4.0mm from the
pilot pipe work, is there a spark
when the system is operated?
Has the ignition lead
become detached from the
control box?
Replace the lead, retry.
Correct and retry.
Check handset batteries are OK.
Replace if required. Check handset
is on manual. Check if handset lock
is off. Check batteries to the control
unit. Replace if required. Retry with
handset and touch pad.
Is the control system being
operated correctly?
Check the tab on the pilot
burner is not damaged.
Either repair tab or replace
pilot burner and retry.
Yes
Yes
Yes
No
No
No
Yes
Yes
Yes
No
No
Replace the electrode Replace the ignition
lead and retry.
Is the flue working?
Rectify flue
No
Yes
Yes
Fault Finding Charts
Servicing Instructions
26


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Riva Vision Large MK1 Series Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Riva Vision Large MK1 Series Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 3.57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info