Welcome
Congratulations on purchasing your Riva Vision fire, if
installed correctly Gazco hope it will give you many years of
warmth and pleasure for which it was designed.
The purpose of this manual is to familiarise you with your
appliance, and give guidelines for its installation, operation
and maintenance. If, after reading, you need further
information, please do not hesitate to contact your Gazco
retailer.
WARNING
In the event of a gas escape or if you can smell
gas, please take the following steps:
• Immediately turn off the gas supply at the
meter/emergency control valve
• Extinguish all sources of ignition
• Do not smoke
• Do not operate any electrical light or power
switches (On or Off)
• Ventilate the building(s) by opening doors and
windows
• Ensure access to the premises can be made
Please report the incident immediately to the
National Gas Emergency Service Call Centre on
0800 111 999 (England, Scotland and Wales) , 0800
002 001 (N. Ireland) or in the case of LPG, the gas
supplier whose details can be found on the bulk
storage vessel or cylinder.
The gas supply must not be used until remedial
action has been taken to correct the defect and
the installation has been recommissioned by a
competent person.
1. General
1.1 Installation and servicing must only be carried out by a
competent person whose name appears on the Gas Safe
register. To ensure the engineer is registered with Gas Safe
they should possess an ID Card carrying the following logo:
1.2 In all correspondence, please quote the appliance type and
serial number, which can be found on the data badge
located on a plate under the Main Burner.
1.3 Do not place curtains above the appliance:
You must have 300mm (1’) clearance between the appliance
and any curtains at either side.
1.4 No furnishings or other objects should be placed within
1 metre of the front of the appliance.
1.5 If a shelf is fitted, a distance of 400mm above the appliance
is required.
1.6 If any cracks appear in the glass panel do not use the
appliance until the panel has been replaced.
1.7 This product is guaranteed for 5 years from the date of
installation, as set out in the terms and conditions of sale
between Gazco and your local Gazco retailer. Please
consult with your local Gazco retailer if you have any
questions. In all correspondence always quote the Model
Number and Serial Number.
IMPORTANT: NEVER position a television or
screen above this appliance.
2. Operating the Appliance
The appliance is operated by thermostatic remote control.
Up
Down
1
2.1 Turning the appliance On
Your remote can control the gas fire from pilot ignition
through to shut down.
To turn the fire on press the OFF button and the UP button
simultaneously. You hear several short signals.
The pilot and main burner ignite and the remote is now
in Manual Mode:
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT OR
BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.
User Instructions
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco riva Vision Large Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco riva Vision Large Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 3.5 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info