IGNITION FUNCTIONAL CHECK 1
PILOT WILL NOT LIGHT
Ensure there is no debris around the pilot assembly,
(e.g. soot, etc.) which could short the spark, clean the area.
Operate the valve.
Is there a spark?
Consult User
Instructions and retry.
Check alignment of pilot
burner head, change the
ignition lead.
See Replacing Parts, section 2.
Check isolation tap and
gas meter, retry.
Correct and
retry.
Purge the gas pipes and retry.
GO TO THE NEXT
CHART IGNITION
FUNCTIONAL CHECK 2
SYSTEM OK
There is a blockage in the system, check the inlet test point,
the mag seating and valve. Check thermocouple leads for correct orientation,
condition and connection
Is the gas turned on to the
appliance?
Is the gas pressure correct?
Has the system got
any air in it?
Does the pilot light?
Is the control being
operated correctly?
Will the pilot light
with a match?
No Yes
No
Yes
No
Yes
Yes
No
No
Yes
No
No
Yes
Yes
SERVICING INSTRUCTIONS
SERVICING/FAULTFINDINGCHARTS
1. SERVICING REQUIREMENTS
IMPORTANT – The glass panel on this appliance should be
checked for any signs of damage on the front face of the glass
panel (scratches, scores, cracks or other surface defects). If
damage is observed, the glass panel must be replaced and the
appliance must not be used until a replacement is installed.
Under no circumstances should the appliance be used if any
damage is observed. Please isolate the appliance until a
replacement glass panel has been obtained and installed.
Replacement glass panels can be purchased from Gazco via the
dealer from which the appliance was purchased or any other
Gazco distributor.
This appliance must be serviced at least once a year by a
competent person.
All tests must be serviced by best practice as described by the
current Gas Safe recommendations.
1.1 Before any tests are undertaken on the stove:
• Conductagassoundnesstestforthepropertytoensure
there are no gas leaks prior to starting work.
1.2 • Fullychecktheoperationofthestove
Special checks
1.2.1 Clean any lint or fluff from the pilot - pay particular
attention to the aeration hole in the side of the pilot
1.2.2 Clean away any fluff or lint from under the burner
1.2.3 Check the spark gap on the pilot is correct
•Correctanyfaultsfoundduringtheinitialtests
•Re-commissionthestoveconductingtheusualsafety
checks
1.3 Advise the customer of any remedial action taken.
REPLACE BATTERIES BEFORE ATTEMPTING TO RECTIFY ANY
FAULTS
IF THE FIRE DOES NOT WORK, BUT HAS WORKED IN THE
PAST:
•CHECKTHEEMERGENCYSHUTOFFSWITCH,
(BOTTOM RIGHT CORNER BY THE DOOR), IS
SWITCHED ON, SEE USER SECTION, PAGE 6
ELECTRONIC CONTROL VALVE FAULT ANALYSIS
Symptom Cause Remedy
3 short beeps from
control
Batteries low in ap-
pliance
Replace appliance
batteries
No ignition, 5 seconds
continuous tone (there
can be several short
beeps before)
1. ON/OFF switch
is in OFF position
2. Loose/damaged
wire
1. Move switch to
ON position
2 Check interrupter
block and wires
No ignition, no tone, mo-
tor turned slighted when
operated
Receiver board
damaged
Replace receiver
No pilot ame and control
continues to spark
Thermocouple
circuit wired incor-
rectly
Correct wiring
Pilot lights, control contin-
ues to spark, vale shuts
down after 10-30 seconds
1. No spark at pilot
burner
2. Loose/damaged
wire
1. Rectify spark at
pilot burner
2. Check interrupter
and wires
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Riva VISION LARGE 8000 series Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Riva VISION LARGE 8000 series Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 0.86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info