INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
1. FLUE AND CHIMNEY REQUIREMENTS
WHEN INSTALLING A FLUE SYSTEM PLEASE REFER TO
THE MANUFACTURER’S INSTRUCTIONS.
The European chimney standards now describe chimneys
and flues by their temperature, pressure and resistance to
corrosion, condensation and fire. To identify the correct flue
system, the minimum flue specification is shown in the
Technical Specification. Existing chimneys are not covered
by this system.
The flue must be installed in accordance with all local and
national regulations and the current rules in force:
A flexible liner must be continuous from the appliance
spigot to the roof terminal.
The minimum effective height of the flue must be 3
metres (10ft).
The flue must be free from any obstruction.
Any damper plates must be removed or secured in the
fully open position and no restrictor plates fitted.
The chimney should be swept immediately before
installing the appliance, but it need not be swept if you can
see the chimney is clean and free from obstruction
throughout .
2. FLUE OPTIONS
Top Exit only - Twin Wall Rigid
127mm (5”)
A range of Vitreous Enamel Gloss Black flue pipe is
available to compliment the Riva Vision. Please contact
your Gazco retailer for further information.
3. GAS SUPPLY
THIS APPLIANCE IS INTENDED FOR USE ON A GAS
INSTALLATION WITH A GOVERNED METER.
3.1 Make sure local distribution conditions (identification of the
type of gas and pressure) and the adjustment of the
appliance are compatible before installation.
3.2 Ensure the gas supply delivers the required amount of gas
and is in accordance with the rules in force.
3.3 You can use soft copper tubing on the installation and soft
soldered joints outside the appliance and below the fire.
3.4 A factory fitted isolation device is part of the inlet
connection; no further isolation device is required.
3.5 All supply gas pipes must be purged of any debris that may
have entered prior to connection to the appliance.
3.6 The gas supply enters through the LEFT-HAND rear of the
carcass.
3.7 The gas supply must be installed in a way that does not
restrict the removal of the appliance for servicing and
inspection.
4. VENTILATION
IMPORTANT: Ensure any national ventilation
requirements are taken into account during installation
of the fire.
UK ONLY:
The Riva Vision has a nominal input not exceeding 7.0kW
and does not normally require any additional permanent
ventilation.
FOR THE REPUBLIC OF IRELAND REFER TO THE RULES
IN FORCE FOR VENTILATION REQUIREMENTS.
5. APPLIANCE LOCATION
5.1 This appliance has been designed to stand on either a
hearth or an optional bench:
RVACLB100B - Riva Bench Low (100cm wide)
RVACB100B - Riva Bench (100cm wide)
RVACLB120B - Riva Bench Low (120cm wide)
RVACB120B - Riva Bench (120cm wide)
RVACLB140B - Riva Bench Low (140cm wide)
RVACB140B - Riva Bench (140cm wide)
5.2 To Install the Bench:
Follow Section 1 Installation - All Models in Installation
guide PM205 supplied with the bench kit.
5.3 To secure the appliance to the bench:
You must consider where you place the appliance on the
bench before using the template. Diagram 1.
1
AR1894
Using the template provided with this appliance as a
guide to the final position of the fire:
1. Mark and drill the holes.
2. Fix the two brackets to the bench. For details refer to
Section 2 Installation in this manual.
3. Position the appliance on the bench lining up the holes
in it's base with the fixing plates and follow the instructions
in Section 2.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Riva VISION LARGE 8000 series Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Riva VISION LARGE 8000 series Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 0.86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info