INSTALLATION INSTRUCTIONS
INSTALLATION/COMMISSIONING
TOUCH PAD CONTROL
24
AR1885
Press the ON-OFF button to light the appliance, (up to 30
seconds).
Press the UP button to increase the flame height.
Press the DOWN button to decrease the flame height. At
the lowest point it goes to ‘standby mode’, (only pilot lit).
Press the ON-OFF button to turn the appliance off.
1. COMMISSIONING
1.1 Complete the Commissioning Checklist at the front of this
manual covering:
Flue checks.
Gas checks.
Log/Stone Chippings layout - flame picture.
For working pressure test, use the access panel at the gas
connection ensuring the burner is in position.
1.2 In the unlikely event that the appliance is receiving
interference from other electronic devices, re-programme
thehandset/Controlbox
Reprogramminghandset/Controlbox
To access the control box see Servicing Instructions,
Section 7 - Main Control Assembly.
Press and hold the reset button on the control box until you
hear two signals. After the second longer signal:
Release the reset button and within 20
seconds
Press the DOWN button on the handset until
you hear an additional long signal
confirming the new code
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco RIVA VISION LARGE 8000 series Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco RIVA VISION LARGE 8000 series Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 1.05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info