813420
24
Zoom out
Zoom in
Previous page
1/36
Next page
24
Commissioning
1. Commissioning
1.1 Complete the Commissioning Checklist at the front of this
manual covering:
— Flue checks
— Gas checks
— Log layout - flame picture
For working pressure test, use the access panel at the gas
connection ensuring the burner is in position. Refer to
Replacement Parts, Section 17.
1.2 Ensure all safety checks listed in the Commissioning
Section are completed, paying particular attention to the
glass panel checks and securing of the glass frame.
1.3 Upon completion of the commissioning and testing of the
installation and correct operation of the appliance, the
installer must instruct the user how to operate the appliance.
1.4 Guide the user through the User Instructions paying
particular attention to:
a) Regular servicing (Section 9 of the User Instructions).
b) Ventilation (Section 10 of the User Instructions) - point out
the ventilation positions where applicable.
c) Hot surfaces (Section 12 of the User Instructions).
d) How the appliance works with the remote control handset
and the modes of operation (Section 2 of the User
Instructions).
e) How to change settings in the auto mode and program
modes of operation.
f) What to do if the appliance fails to operate (Section 13 of
the User Instructions).
1.5 In the unlikely event that the appliance is receiving
interference from other electronic devices,
re-programme the handset/Control box.
Reprogramming handset/Control box
To access the control box see Servicing Instructions,
Section 6 - Main Control Assembly.
— Press and hold the reset button on the control box until
you hear two signals. After the second longer signal:
Release the reset button and within 20 seconds:
— Press the DOWN button on the handset until you hear
two additional short signals confirming the new code is set.
If there is a single long signal the code learning sequence
has failed or the wiring is incorrect.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Riva Vision Large 50000 serie Balanced Flue Instructions at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Riva Vision Large 50000 serie Balanced Flue Instructions in the language / languages: English as an attachment in your email.

The manual is 3.52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info