813420
5
Zoom out
Zoom in
Previous page
1/36
Next page
5
User Instructions
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT OR
BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.
2.2 There are 3 different modes available for controlling and
operating the appliance:
1. Manual Mode
2. Temp Mode (Automatic)
3. Timer Mode (Automatic)
2.3 In MANUAL MODE you can:
turn on the main burner using the UP button
regulate the flame from high to low and back
— turn off the burner leaving just the pilot burning
In TEMP MODE (Automatic) you can:
set the room temperature so the thermostat in the remote
automatically maintains that temperature
In TIMER MODE (Automatic) the fire:
turns on and off according to the set time periods
automatically regulates the room temperature during the
set periods
NOTE: When operating the fire in Temp or Timer mode,
the pilot remains lit and the fire then automatically
switches on at programmed times to bring the room to
the set temperature whether or not you are in the room.
NEVER LEAVE ANY COMBUSTIBLE MATERIALS
WITHIN 1 METRE OF THE FRONT OF THE APPLIANCE.
Switching Between Modes
2.4 Press the SET button to change to Temperature Mode.
Press again to change to Timer Mode.
Keep pressing to run through all operating modes. These
are:
— MAN
— DAY TEMP
— NIGHT TEMP
— TIMER
and back to MAN
NOTE: MAN mode can also be reached by pressing
either the UP or DOWN button.
Manual Mode
2.5 Press the OFF button and the UP button simultaneously.
You hear several clicks and audible beeps as the fire begins
the ignition process, (up to 30 seconds).
Turning the appliance Off:
Press the OFF button to turn the appliance off
FOR SAFETY, YOU MUST WAIT 30 SECONDS BEFORE
LIGHTING THE FIRE AGAIN.
Increasing the Flame Height:
Press the UP button once to increase flame height one stage.
Press and hold the UP button to increase to maximum.
Decreasing the Flame Height:
Press the DOWN button once to decrease flame height
one stage. Press and hold the DOWN button to decrease to
minimum. At the lowest point the fire goes to 'Standby Mode'
(Only Pilot lit).
NOTE: While pressing a button a symbol indicating
transmission appears on the display. The receiver
confirms transmission with a sound signal.
Temp Mode (Automatic)
2.6 The display shows the current room temperature.
To increase or decrease the fire’s output:
Press the SET button to select either the DAY TEMP or the
NIGHT TEMP mode by briefly pressing the SET button.
Hold the SET button until the TEMP display flashes and
then let go.
Set the desired temperature with the UP and DOWN arrows.
(Minimum temperature 5C, maximum 40C or 40F to 99F
when Fahrenheit is the preferred option)
Press the OFF button to stop the display flashing or wait
to return to TEMP mode.
NOTE: If you set a temperature that is beneath the
current room temperature, the fire automatically
switches to PILOT (Stand by).
If you would like the Night temperature control to turn
off then decrease the temperature until [--] is displayed.
Timer Mode (Automatic)
2.7 There are two programmable settings you can make over a
24 hour period, P1 and P2. These are normally used to
provide an early morning and evening setting for each
working week:
P1 + = Start Timed Setting 1
P1 + = End of Timed Setting 1
P2 + = Start Timed Setting 2
P2 + = End of Timed Setting 2
2.8 P1 - Program 1 for a Timed Setting
Press the SET button until the TIMER mode is displayed.
Hold the SET button. The displays flashes the current time
for P1. While the time displayed is flashing you can alter
the hours and minutes set.
To set the time your fire first lights, change P1
— Press the UP button to alter the hour.
Press the DOWN button to alter the minutes
in 10 minute increments.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Riva Vision Large 50000 serie Balanced Flue Instructions at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Riva Vision Large 50000 serie Balanced Flue Instructions in the language / languages: English as an attachment in your email.

The manual is 3.52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info