813398
38
Zoom out
Zoom in
Previous page
1/52
Next page
38
CONTROL ASSEMBLY &
SERVICE HATCH
It is not necessary to remove the complete control
assembly to service or replace parts of this appliance.
The following sections will detail how to individually
remove and replace each element.
1
Gas Valve Pilot Valve
Mag
Unit
Ignition
Lead
2
Reposition the service hatch and tighten the 4
screws.
Ceramic Gasket
face down
3
PILOT UNIT
IMPORTANT: UNDER THE TERMS OF THE
EXTENDED WARRANTY IT WILL BE COMPULSORY
TO CHANGE THE COMPLETE PILOT UNIT ON THIS
APPLIANCE IN YEARS 2 AND 4.
The pilot assembly consists of 4 components which can be
individually changed:
a) Pilot burner bracket.
b) Electrode.
c) Pilot injector.
d) Thermocouple.
Electrode
Thermocouple
Pilot Injector
Pilot Burner
Bracket
Ignition Lead
Pilot Pipe
Screw Screw
NOTE: Ensure the sealant surrounding the Electrode and
Thermocouple leads is replaced if disturbed or removed whilst
gaining access to these components.
Turn the gas supply off at the isolation device, remove the door
and place to one side, carefully remove the ceramic fuel bed
components.
PILOT BURNER BRACKET
First remove the electrode, pilot pipe and
thermocouple as described in the following sections.
15
38


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Loft Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Loft Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 8.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info