FLUE OPTIONS
Consult the rules in force.
NOTE: This appliance does not normally require any additional
ventilation when installed in GB.
A range of Vitreous Enamel Gloss Black ue pipe is available
to compliment the appliance. Please contact your Gazco
retailer for further information.
GAS SUPPLY
THIS APPLIANCE IS INTENDED FOR USE ON A GAS
INSTALLATION WITH A GOVERNED METER.
Before installation, ensure that the local distribution conditions
(identication of the type of gas and pressure) and the adjustment
of the appliance are compatible.
Ensure the gas supply delivers the required amount of gas and is in
accordance with the rules in force.
You can use soft copper tubing on the installation and soft soldered
joints outside the appliance and below the re.
A factory tted isolation device is part of the inlet connection; no
further isolation device is required.
All supply gas pipes must be purged of any debris that may have
entered prior to connection to the appliance.
The gas supply must be installed in a way that does not restrict the
removal of the appliance for servicing and inspection.
VENTILATION
IMPORTANT: Ensure any national ventilation requirements are
taken into account during installation of the re.
UK ONLY:
The appliance has a nominal input not exceeding 7.0kW and does
not normally require any additional permanent ventilation.
FOR THE REPUBLIC OF IRELAND REFER TO THE RULES IN
FORCE FOR VENTILATION REQUIREMENTS.
APPLIANCE LOCATION
Once the position of the appliance has been decided:
Follow the instructions for securing the appliance on Page 20.
The non-combustible hearth must be at least 12mm thick, and
project a minimum of 50mm from the base of the appliance in all
directions.
The appliance is not suitable for installation against a combustible
wall. A combustible side wall must be a minimum of 200mm.
This appliance can be installed with an up and out ue (vertical wall
- horizontal ue) or with a vertical ue with roof termination (see
Site Requirements, Flue Options).
HEARTH INSTALLATION
(NOT APPLICABLE FOR BASE SECTION INSTALLATIONS
MODELS)
Building Regulations state this appliance must stand on a non-
combustible hearth that is at least 12mm thick and projects 50mm
minimum from the base of the appliance in all directions, however
Gazco recommend the hearth extends to the following dimensions,
see Diagram.
CA
B
Dimensions A B C
All Models 781mm 498mm 12mm
BASE SECTION INSTALLATION
It is not necessary to site these products on a non-combustible
floor. However, for practical reasons, the floor should be flat and
solid to allow the appliance to be levelled and secured in place.
This appliance may be situated anywhere in the room, but due
consideration should be taken to ensure that it is sited within the
constraints of the allowable flue configuration.
DO NOT INSTALL APPLIANCE ON A CARPET.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Loft Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Loft Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 8.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info