813397
49
Zoom out
Zoom in
Previous page
1/60
Next page
49
CONTROL BOX
1
2
1
2
4
3
The control box can now be replaced.
When replacing the sealing plate on the rear of the control cover
use a suitable silicone sealant.
Pilot Burner 8 Wire Cable
Ignition Cable
Interrupter Block
Reset Button
GV60 Valve
Battery Cable/ Mains
Adaptor (Optional)
Thermocurrent
Cable SW
Thermocurrent
Cable TC
After replacing the control box you may need to
reprogram the handset.
— Press and hold the reset button on the control box
until you hear two signals. After the second longer
signal:
— Release the reset button and within 20 seconds:
— Press the DOWN button on the handset until you hear
two additional short signals confirming the new code is
set.
If there is a single long signal the code learning sequence
has failed or the wiring is incorrect.
MAIN INJECTOR
IMPORTANT: TURN OFF THE GAS SUPPLY AT
THE ISOLATION DEVICE.
1
2
1
2
3
Injector
Nut
49


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Loft Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Loft Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 9.44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info