813397
48
Zoom out
Zoom in
Previous page
1/60
Next page
48
GAS VALVE
IMPORTANT: TURN OFF THE GAS SUPPLY AT
THE ISOLATION DEVICE.
1
2
1
2
15
Gas Valve
Injector
3
4
Disconnect
5
61
1
2
Replace in reverse order.
Check all joints for gas leaks and check operation of the
thermocouple and ignition lead.
MAGNETIC SAFETY VALVE
IMPORTANT: TURN OFF THE GAS SUPPLY AT
THE ISOLATION DEVICE.
Remove the gas valve.
Undo the magnetic valve-retaining nut from the back of the control
valve.
Gently tap out the magnetic valve and replace with a new unit.
Replace the retaining nut and tighten.
Reassemble the interrupter block and leads and secure the
thermocouple connection in the rear of the gas control.
(Do not overtighten).
Turn the gas supply on and check the entire pipework and valve
joints for any leaks.
48


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Loft Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Loft Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 9.44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info