SITE REQUIREMENTS
This kit provides the minimum materials. Extra lengths can be
added to the vertical and horizontal sections.
Refer to Technical Specication to identify when to use a restrictor.
TOP FLUE UP AND OUT WITH
ADDITIONAL BEND
An additional bend can be used on the horizontal section (45° or
90°) but the overall horizontal ue is reduced.
When A = 1.0 to 1.499 metres B+C = 1.0 metre max (Nat Gas - No restrictor,
LPG - 75mm Restrictor)
When A = 1.499 to 3.0 metres B+C = 4.0 metres max (Nat Gas - 70mm restrictor,
LPG - No restrictor)
EITHER 45˚
OR 90˚
TOP FLUE VERTICAL KIT
This ue is vertical from the top of the appliance, see Diagram.
A minimum vertical rise of 2m to a maximum of 10m.
8524/8524AN
The basic kit comprises:
2 x 1m lengths
1 x vertical Flue Terminal
1 x 1m terminal lengths
1 x 52mm restrictor
1 x 47mm restrictor
1 x 60mm restrictor
1 x 70mm restrictor
Extra lengths can be added.
Refer to Technical Specication to identify when to use a restrictor.
IMPORTANT:
1M VERTICAL, TERMINAL AND STRAIGHT FLUE
LENGTHS MUST NOT BE CUT!
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Loft Balanced Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Loft Balanced Flue in the language / languages: English as an attachment in your email.

The manual is 9.44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info