GENERAL
IMPORTANT: ALWAYS WEAR THE GLOVES
PROVIDED WHEN HANDLING AN IVORY PAINTED
APPLIANCE.
All main components can be replaced without removing the
appliance from its installation.
Ensure the appliance and surrounds are cool before servicing.
IT IS ESSENTIAL THAT THE GAS SUPPLY TO THE APPLIANCE
IS TURNED OFF AT THE ISOLATION DEVICE BEFORE
PROCEEDING FURTHER.
To service the gas valve and controls the decorative trim can be
removed to allow easier access. To do this remove the two screws
and gently pull away from the appliance.
REMOVING THE DOOR
IMPORTANT: THE OUTER PANELLING OF THE
APPLIANCE IS MADE FROM CAST IRON. USE
CAUTION WHEN INSTALLING, REMOVING AND
STORING AS THE COMPONENTS ARE HEAVY
AND SHOULD BE HANDLED CAREFULLY.
For rear flue exit lift the top of the appliance off and put to one
side.
For top flue exit lift and support the top to give clearance.
HUNTINGDON 20 AND 40
Lift the front upwards until it is clear of the slots and pull away from
the appliance.
HUNTINGDON 30
Lift the front upwards until it is clear of the slots and pull away from
the appliance.
REPLACING PARTS
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Huntingdon 20-30-40 - Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Huntingdon 20-30-40 - Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 13.82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info