813395
14
Zoom out
Zoom in
Previous page
1/32
Next page
14
INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
9. INSTALLATION OF THE GAS SUPPLY
9.1 Before installation ensure the stove is compatible with the
local gas type and pressure.
9.2 Ensure the gas supply delivers the required amount of gas in
accordance with the rules in force.
9.3 Soft copper tubing and soft soldered joints must be no
closer than 50mm to the base of the burner unit.
9.4 Ensure there is a means of isolating the gas supply
independent of the stove's controls.
9.5 All gas supply pipes must be purged of any debris before
connection to the stove.
10. STOVE LOCATION
10.1 This stove must stand on a non-combustible hearth that is at
least 12mm thick and projects 50mm minimum from the
base of the stove in all directions (see Diagram 6).
AR0604
A = 700mm
B = 390mm
C = 12mm
CA
B
6
MINIMUM CLEARANCE
10.2 The stove is not suitable for installation against a
combustible wall. All combustible materials must be
removed from behind the stove.
10.3 Ensure that all minimum clearances to combustible
materials are complied with (see Diagrams 7 and 8).
AR0522
150
225
150
7
8
50mm
150mm
AR0531
10.4 The above dimensions provide adequate clearance to
combustible materials. It may be necessary to add
additional clearance so that the controls can be reached
and spillage tests performed when necessary.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco F40 Avanti Balanced Log at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco F40 Avanti Balanced Log in the language / languages: English as an attachment in your email.

The manual is 3.87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info