3. Rear Flue (8526)
200mm min
600mm max
2
Terminal dimensions:
395 x 200 x 200 mm (H x W x D)
Guard supplied
Cut to length as required on site, see Diagram 2.
4. Top Exit Flues
There are two types of flue terminal: horizontal and vertical.
For vertical see Section 4D.
4A. For horizontal terminal installations
4.1 Decide on the terminal position.
4.2 Measure the height from the top of the appliance to the
centre of the required hole. For minimum and maximum
dimensions see Diagram 3.
4.3 To fit the flue you must have access to the top or the side of
the appliance to connect the flue.
4.4 Assemble the vertical sections first.
4.5 Add the 90° elbow.
4.6 Add the horizontal section and terminal.
4.7
A masonry installation requires the addition of a suitable lintel
to support the opening.
Only the horizontal terminal section can be reduced in size.
Refer to
Installation Instructions, Technical Information
for
details of flue length.
4B. Top Flue Up and Out Kit
(8523/8523AN)
4.8 This flue rises vertically from the top of the appliance, then
continues horizontally outward, see Diagram 3.
The basic kit comprises:
1 x 500mm vertical length
1 x 500mm terminal length (cut to length on site)
1 x 90 degree elbow
1 x wall plate
1 x 75mm restrictor fixing screws
4.9 This kit provides the minimum materials. Extra lengths can
be added to the vertical and horizontal sections; refer to
Section 5.
3
4.10 Refer to Installation Instructions, Technical Specification to
identify when to use a restrictor.
4C. Top Flue Up and Out
with Additional Bend
4.11 An additional bend can be used on the horizontal section
(45° or 90°) but the overall horizontal flue is reduced, see
Diagram 4.
(No restrictor)
When A = 1.0 to 1.499 metres
B+C = 1.0 metre max
When A = 1.499 to 3.0 metres
B+C = 4.0 metres max
(75mm diameter
restrictor)
A
C
B
Either 45° or 90°
90°
4
Installation Instructions
Site Requirements
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Clarendon - Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Clarendon - Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 2.41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info