INSTALLATION INSTRUCTIONS
INSTALLATION / COMMISSIONING
1. COMMISSIONING
1.1 Close all doors and windows in the room. Ignite the
appliance and operate on maximum for 10 minutes.
Remove the plastic sight plug from the right-hand side of
the appliance. Position a lighted smoke match just inside
the draught diverter opening and check that all smoke is
drawn into the opening. Watch through the viewing hole in
the side of the casing. In restricted locations a mirror can be
used (see Diagram 1). If there is any doubt, run the
appliance for a further 10 minutes, and repeat the test.
1
AR0539
1.2 If there are any extractor fans in adjacent rooms, the test
must be repeated with the fans running on maximum and
interconnecting doors open.
IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE
AND SEEK EXPERT ADVICE.
For future reference record the installation details on the
Appliance Commissioning Checklist on page 3 of these
instructions.
AR0390
22
NEVER OPERATE THE APPLIANCE WHEN THE DOOR IS
REMOVED OR WHEN THE GLASS IS BROKEN.
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Clarendon - coal at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Clarendon - coal in the language / languages: English as an attachment in your email.

The manual is 3.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info