SITE REQUIREMENTS
SAFETY PRECAUTIONS
For your own and others safety, you must install this appliance
according to local and national codes of practice. Failure to install
the appliance correctly could lead to prosecution. Read these
instructions before installing and using this appliance.
These instructions must be left intact with the user.
Do not attempt to burn rubbish on this appliance.
Keep all plastic bags away from young children.
Do not place any object on or near to the appliance and allow
adequate clearance above the appliance.
IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN USE,
WAIT 3 MINUTES BEFORE ATTEMPTING TO RELIGHT THE
APPLIANCE.
IMPORTANT: REFER TO DATA BADGE AND
TECHNICAL SPECIFICATION AT THE FRONT OF
THE MANUAL TO ENSURE THE APPLIANCE IS
CORRECTLY ADJUSTED FOR THE GAS TYPE AND
CATEGORY APPLICABLE IN THE COUNTRY OF
USE.
FOR DETAILS OF CHANGING BETWEEN
GAS TYPES REFER TO SERVICING SECTION
REPLACING PARTS.
FLUE & CHIMNEY REQUIREMENTS
WHEN INSTALLING A FLUE SYSTEM PLEASE REFER TO THE
MANUFACTURERS INSTRUCTIONS.
The European chimney standards now describe chimneys and
flues by their temperature, pressure and resistance to corrosion,
condensation and fire. To identify the correct flue system, the
minimum flue specification is shown in the Technical Specification.
Existing chimneys are not covered by this system.
The chimney or flue system must comply with the rules in force,
and must be a minimum of 127mm (5") in diameter.
A 127mm liner must be used if fitting the appliance into an existing
brick built chimney.
Larger lined flues can work, but in some instances could cause
cold start flue problems resulting in nuisance shutdown. Lined flues
above 175mm are not recommended.
Suitable systems are:
a) Flexible liner which must be continuous from the appliance
spigot to the roof terminal.
b) Gazco Linerless kit.
UNDER NO CIRCUMSTANCES MUST THE LINERLESS KIT BE
USED WITH ANY INSTALLATION OTHER THAN AN EXISTING
MASONRY CHIMNEY WHICH HAS A MINIMUM DIAMETER OF
178mm. THE CHIMNEY MUST BE SOUND AND CLEAN. IF
PREVIOUSLY USED FOR SOLID FUEL, IT MUST BE SWEPT
PRIOR TO PROCEEDING WITH THE INSTALLATION.
NOTE: If the Linerless kit is to be used, due care should be taken
to prevent condensation forming in the chimney. Do not fit the
Linerless Kit if the chimney is taller than 10 metres (external wall)
or 12 metres (internal wall).
The minimum flue height for the appliance must be 3 metres. Any
horizontal flue run from the rear outlet must not exceed 100mm
from the back of the appliance.
The chimney or flue must be free from any obstruction. Any
damper plates must be removed or secured in the fully open
position, and no restrictor plates fitted.
The chimney must be swept prior to the installation, but it need not
be swept if it can be seen the chimney is clean and unobstructed
throughout its entire length.
Steel Register
Plate with Clamp
that holds the Flex
Adapter
Flex Pipe Adapter
connects to stove
ue pipe
Stove Flue Pipe
running from the
stove to the Flex
Pipe Adapter
Stove
FLUE OPTIONS
A range of Vitreous Enamel Gloss Black flue pipe is available
to compliment the appliances. Please contact your Gazco
retailer for further information.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Chesterfield - Conventional Flue at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Chesterfield - Conventional Flue in the language / languages: English as an attachment in your email.

The manual is 8.08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info