9
1.2 REAR FLUE 8526
Terminal dimensions:
395 x 200 x 200 mm (H x W x D)
Cut to length as required on site.
Guard Supplied.
1.3 TOP EXIT
Two types of top exit flue terminal are available, horizontal
and vertical. For a horizontal terminal, decide on the
terminal position and measure the height from the top of the
appliance to the centre of the required hole. For minimum
and maximum flue dimensions see diagram 3.
Access must be either above or at the side of the installation
to allow the flue to be assembled on top of the appliance.
When a horizontal terminal is used, the vertical sections are
assembled first, then the 90-degree elbow and finally the
horizontal section including the terminal. If a masonry
installation is to be built, a suitable lintel must be used to
support the opening.
Only the horizontal terminal section can be reduced in size.
Refer to Balanced Flue Technical Information for details of
flue length.
1.4 TOP FLUE UP & OUT KIT (8523/8523AN)
Vertical from the top of the appliance then horizontally out.
(See diagram 3.)
The basic kit comprises:
1 x 500mm vertical length
1 x 500mm terminal length (cut to length on site)
1 x 90 degree elbow
1 x wall plate
1 x 75mm restrictor fixing screws
The kit is the minimum required. Extra lengths may be
added to the vertical and horizontal (see section 1.5), with
reference to Diagram 3.
Extra lengths may be added (see section 1.5), with reference
to diagram 3 and the installation instructions of the
appliance.
Refer to Table A under 3.2, Installation for identifying when
to use the restrictor.
INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
2
AR0630
3
AR1619
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Ceramica Manhattan 8537LUC - P8537LUC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Ceramica Manhattan 8537LUC - P8537LUC in the language / languages: English as an attachment in your email.

The manual is 4.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info