SERVICING INSTRUCTIONS
REPLACING PARTS
9.5 Refit the new sensor, ensuring that the plastic spacers are
between the sensor and the bracket. Refit the leads. See
Diagram 20.
9.6 Feed the cable back through the hole as you replace the
bracket. When the bracket is located correctly it will sit
flush with the back panel without force required. If not
positioned correctly the bracket will sit at an angle. See
Diagram 21.
10. PRIMARY AERATION PLATE
10.1 Turn the gas supply off at the isolation device.
10.2 Refer to Section 2 to remove the main burner.
10.3 Remove the two screws on the burner skin to detach the
venturi cover from the venturi. Slide the venturi cover off the
venturi as per diagram 22.
10.4 Change the aeration plates to those stated in the technical
specification for the gas the product will be using, refer to
the databadge.
NOTE: EVEN IF NO AERATION PLATE IS REQUIRED, THE
SMALL SCREW MUST BE REPLACED.
11. CHANGING BETWEEN GAS TYPES
In order to change between gas types, it will be necessary to
change the following items.
- Pilot Injector
- Control Valve
- Main Injector
- Main Burner
- Aeration Plate (if required)
- Databadge
The relevant parts can be ordered from Gazco, always quote
the appliance type and serial number when ordering spare
parts.
** NOTE: THE CONTROL VALVE IS FACTORY PRESET
FOR CORRECT GAS TYPE AND MODEL, A NEW UNIT
WILL NEED TO BE ORDERED WHEN CHANGING
BETWEEN GAS TYPES.
AR0619
23
AR1608
22
AR1452
20
AR1447 AR1448
21
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Ceramica Manhattan 8615LUC P8615LUC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Ceramica Manhattan 8615LUC P8615LUC in the language / languages: English as an attachment in your email.

The manual is 4.09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info