Installation Instructions
6.11 Replace ALL of the securing nuts ensuring that a nut is
present on all fixing studs.
UNDER NO CIRCUMSTANCES SHOULD THE
APPLIANCE BE USED IF ANY OF THE DOOR
RETAINING NUTS ARE LOOSE OR MISSING.
7. Operating the Appliance
7.1 Locate the control valve on the appliance. It has two
controls, see Diagram 20:
1. The right-hand knob controls the pilot ignition.
2. The left-hand knob controls the main burner.
20
7.2 Refer to separate instructions if your appliance is upgraded
to include battery remote control. The instructions below
apply whether or not you have the remote upgrade.
Lighting the Pilot
7.3 To start the left-hand and right-hand control knobs must both
point to off ( ):
7.4 Press in the right-hand control knob and rotate anti-
clockwise until a click is heard. Continue to press in. The
knob points to the pilot ( ).
The pilot is lit.
7.5 Keep the knob depressed for 10 seconds before releasing.
The pilot remains lit.
Repeat the above steps if the pilot does not stay lit.
NOTE: If the pilot goes out, the Interlock system
prevents you lighting again for a short period.
7.6 If, after repeating the above steps the pilot does not light,
contact your Retailer or Installer.
7.7 Turn the right-hand knob to the left to main burner setting
( ).
Adjusting the Flame height
7.8 You can now adjust the flame height and temperature using
the left-hand control knob.
7.9 Turn the left-hand knob anti-clockwise to increase the
flame height.
7.10 Turn clockwise to decrease the height.
IMPORTANT: YELLOW FLAMES TYPICALLY
APPEAR WHEN THE APPLIANCE HAS REACHED
NORMAL OPERATING TEMPERATURE. THIS CAN
TAKE UP TO 30 MINUTES.
WARNING: IF THE APPLIANCE FAILS TO LIGHT OR
BECOMES EXTINGUISHED IN USE, WAIT 3
MINUTES BEFORE ATTEMPTING TO RELIGHT.
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Ashdon - Balanced Flue -Gas at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Ashdon - Balanced Flue -Gas in the language / languages: English as an attachment in your email.

The manual is 2.41 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info