8.2 Rotate the injector until it is fully removed, and install the
correct replacement injector. Reassemble and turn the gas
supply on, check for leaks.
9. GAZCO FLUE SURE SYSTEM
If the appliance has been installed in a restrictive location, it
may be necessary to remove the appliance from its location.
9.1 Locate the sensor in the draught diverter opening, and
gently pull the two wires off the terminals. Undo the two
taptite screws and remove the sensor and the two plastic
spacers (see Diagram 14).
AR0380
14
9.2 Refit a new sensor ensuring the spacers are located between
the sensor and the bracket. Replace the two leads.
9.3 If it has been necessary to remove the appliance, ensure
that all disturbed gas joints are checked for gas soundness
when reinstalled, and repeat the flue clearance test as
detailed in the Commissioning Section.
10. PRIMARY AERATION PLATE
10.1 Turn the gas supply off at the isolation device.
10.2 Locate the aeration plate on the underside of the airbox
and remove the Nyloc nut (see Diagram 15).
AR0381
15
10.3 Remove the plate and replace with the correct size, ensure
that the hole(s) in the plate align correctly with the holes in
the underside of the airbox and replace the Nyloc nut.
11. CHANGING BETWEEN GAS TYPES
11.1 In order to change between gas types, it will be necessary to
change the following items:
•PilotUnit
•ControlValve
•MainInjector
•AerationPlate(ifrequired)
•Databadge
The relevant parts can be ordered as a conventional kit
from Gazco. Always quote the appliance type and serial
number when ordering spare parts.
**NOTE: THE CONTROL VALVE IS FACTORY PRESET
FOR CORRECT GAS TYPE AND MODEL. A NEW UNIT
WILL NEED TO BE ORDERED WHEN CHANGING
BETWEEN GAS TYPES.
12. CONTROL UPGRADE
See Installation, Section 1.
SERVICING INSTRUCTIONS
REPLACING PARTS
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gazco Ashdon - Coal at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gazco Ashdon - Coal in the language / languages: English as an attachment in your email.

The manual is 3.18 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info