Rev. 4 Page 2-25
2.4.6 Placards and Labels
All placards and labels must be readable in all cockpit lighting conditions. Ambient flood lighting is
acceptable. Placards added as part of the GTN and GMA 35 installation must be displayed in a
conspicuous place and must not be easily erased, disfigured, or obscured. Text height must be a minimum
of 0.10 inch, and the text must contrast with the placard surroundings such that it is easily readable. The
text must be a high-quality, solid-color font of at least 300 DPI (dots per inch). Dot-matrix fonts are
unacceptable.
New circuit breakers and switches installed for the GTN or GMA 35 unit must be labeled as shown in the
applicable interconnect drawing in Appendix E or Appendix F.
2.4.7 Power Distribution
For the purpose of this section, an avionics bus is considered to be any group of circuit breakers fed from
a common source or multiple sources with a remote switch for the intent of controlling the power to
avionics equipment.
2.4.7.1 Circuit Protection
Circuit protection devices for the GTN and GMA 35 must be push-pull manually resettable circuit
breakers (e.g. Klixon 7274 or 7277 Series circuit breakers). Refer to Figure E-4 for GTN circuit breaker
ratings or Figure F-2 for GMA 35 circuit breaker ratings. The circuit breakers must be labeled as specified
in the interconnect diagrams in Appendix E and Appendix F and the circuit breakers must be readily
accessible to the pilot.
A single circuit breaker must be dedicated to the GTN Main and NAV power inputs as shown in
Figure E-4. A single circuit breaker must also be dedicated to the COM input for the GTN 635/650/750.
See Figure E-4 for more information. Do not combine more than one unit on the same circuit breaker.
2.4.7.2 Power Distribution – Single GTN, Aircraft Weight Less than 6000 Pounds
When one GTN is installed in aircraft with a maximum certified gross takeoff weight of less than 6000
pounds, the GTN should be connected to the avionics bus. The NAV/GPS and COM circuit breakers
(Reference Figure E-4) must be connected to the same avionics bus.
When the GTN is the second NAV/COM unit being installed in the aircraft, the GTN should be connected
to the avionics bus. The NAV/GPS and COM circuit breakers (Reference Figure E-4) must be connected
to the same avionics bus. The GTN and other NAV/COM must be grounded at separate ground
terminal/stud locations on the aircraft. The power and ground wiring for the GTN should be routed
separately from the power and ground wiring for the other NAV/COM. This method, shown in
Figure 2-11, will maximize system redundancy if the ground connection for one radio fails.
Avionics Bus
GTN 6XX/7XX
COM
Ground Plane
Other NAV/COM
Figure 2-11. Power and Ground Distribution -
Single GTN, Aircraft Weight Less Than 6000 lb
67


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Garmin GTN 650 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Garmin GTN 650 in the language / languages: English as an attachment in your email.

The manual is 8,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info