691268
10
Zoom out
Zoom in
Previous page
1/50
Next page
The compass indicates your directional heading .
2
Select to set the heading.
The compass indicates deviations from the set heading .
3
Select , and select an option:
To reset the heading, select Reset Heading.
To change the heading by 180 degrees, select Set to
Recip..
NOTE: The compass indicates the reciprocal heading with
a red mark.
To set to a 90-degree heading left or right, select Set to
90L or Set to 90R.
To clear the heading, select Clear Heading.
Viewing Additional Gas Dive Data
During a single-gas, multi-gas, closed-circuit rebreather, or
gauge dive, scroll to the third data screen.
Your current heart rate zone (About Heart Rate Zones,
page 18).
NOTE: You can view only wrist heart rate monitor data during a
dive.
Gray: Zone 1.
Blue: Zone 2.
Green: Zone 3.
Orange: Zone 4.
Red: Zone 5.
Your central nervous system (CNS) oxygen toxicity level during
a single-gas, multi-gas, or closed-circuit rebreather dive.
Green: 0 to 79% CNS oxygen toxicity.
Yellow: 80 to 99% CNS oxygen toxicity.
Red: 100% or greater CNS oxygen toxicity.
Using the Dive Stopwatch
TIP: You can add a simplified stopwatch screen to any of the
gas dive modes (Customizing the Data Screens, page 26).
1
Start a Gauge dive.
2
Scroll to the stopwatch screen.
3
Select > Reset Avg. Depth to set the average depth to
your current depth.
4
Select > Start Stopwatch.
5
Select an option:
To stop using the stopwatch, select > Stop Stopwatch.
To restart the stopwatch, select > Reset Stopwatch.
Diving with the Map
You can view the map during apnea surface intervals.
1
During an apnea dive activity, scroll to the map.
2
Select , and select an option:
To pan or zoom the map, select Pan/Zoom.
TIP: You can select to toggle between panning up and
down, panning left and right, or zooming. You can hold
to select the point indicated by the crosshairs.
To mark your location, select Save Location.
TIP: You can select DOWN to change the icon.
Viewing the Surface Interval Widget
The widget displays your surface interval time, tissue load, and
central nervous system (CNS) oxygen toxicity percentage.
1
From the watch face, select UP.
2
Select to view tissue details and oxygen toxicity units
(OTU).
NOTE: The OTU accumulated during a dive expire after 24
hours.
Viewing the Dive Log Widget
The widget displays a brief summary of your last recorded dive.
1
From the surface interval widget, select UP.
2
Select to view more information about a dive.
3
Select a dive.
4
Select an option:
To view additional information about the activity, select
Details.
To view additional information about one of multiple apnea
dives in the activity, select Dives, and select a dive.
To view the activity on a map, select Map.
NOTE: The device shows your entry and exit locations if
you waited for GPS signals before and after the dive.
To view the depth profile of the activity, select Depth
Profile.
To view the temperature profile of the activity, select
Temperature Profile.
Dive Planning
You can plan for future dives using your device. The device can
calculate no-decompression limit (NDL) times or create
decompression plans. When planning a dive, the device uses
your residual tissue load from recent dives in the calculations.
Calculating NDL Time
You can calculate the no-decompression limit (NDL) time or
maximum depth for a future dive. These calculations are not
saved or applied to your next dive.
1
Select > Plan Dive > Compute NDL.
2
Enter an oxygen percentage.
3
Select an option:
To calculate the NDL time, select Enter Depth, and enter
the planned depth for your dive.
To calculate the maximum depth, select Enter Time, and
enter your planned dive time.
The NDL countdown clock, depth, and maximum operating
depth (MOD) appear.
4 Diving
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Garmin Edge 830 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Garmin Edge 830 in the language / languages: English as an attachment in your email.

The manual is 7,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Garmin Edge 830

Garmin Edge 830 User Manual - German - 40 pages

Garmin Edge 830 User Manual - Dutch - 38 pages

Garmin Edge 830 User Manual - French - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info