712180
4
Zoom out
Zoom in
Previous page
1/23
Next page
v Disconnect the pump from the mains
via the main circuit breaker, let the water
cool (approx. 10 – 15 min.) and secure
the water supply on the intake side before
putting into operation again.
Visual check
v Before operating the pump, first make
a visual check to ensure there is no damage
to the pump (especially regarding power
cable and plug).
A damaged pump must not be used.
v In case of damage, please have the pump
checked by our GARDENA Service Centre
or by an authorised electrician.
Safety in operation
Protect the pump from rain. Do not use
the pump in a wet or moist area.
In order to avoid dry-running of the pump,
take care that the end of the suction hose is
always submerged into the water.
v Before each operation, fill the pump to
overflowing with approx. 2 to 3 l of water
to be pumped!
Very fine sand can pass through the integrated
filter (mesh size 0.45 mm) and cause accelera-
ted wear in the hydraulic parts.
v For sandy water, you should additionally use
the GARDENA pump pre-filter, art. no. 1730
(mesh size 0.1 mm).
Please ensure that no unauthorised persons
or children are within reach of the pump and the
pumped medium without supervision.
When using the pump for domestic water
supply, please adhere to the local water and
sewerage regulations. In addition observe
the regulations of DIN 1988.
v If necessary, contact your local water
authority.
Warning! This pump produces an electro-
magnetical field during operation. This field may
under some circumstances interfere with active
or passive medical implants. To reduce the risk
of serious or fatal injury, we recommend
persons with medical implants to consult their
physician and the medical implant manu facturer
before operating this pump.
Danger! Small parts could be swallowed during
assembly and there is a risk of suffocation
from the polybag. Keep infants away during
assembly.
3. Function
The Electronic Pressure Pump is equipped with an electronic
control which automatically turns on the pump when the cut-in
pressure has fallen and automatically switches off when no
more water is extracted.
Low quantity programme: The integrated small amount programme allows for trouble-free
use of, for example, modern washing machines or drip irrigation
systems even with low water flow.
Error diagnosis system: The pump has an error diagnosis system which shows
different fault statuses and their remedies via the display
(see 9. Troubleshooting).
MENU
ß
II
ß
I
Display
Updated information on the operating conditions can be
shown depending on the display, and various settings can be
undertaken.
The display consists of a display area ß
I and a toolbar ß
II ,
which states the respective functions of the 3 buttons below
e.g.:
Left button Scroll menu upwards to
“Leakage warning”.
Centre button Call up the “Turn on pressure” menu.
Right button Scroll menu down to
“Troubleshooting”.
21
GB
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gardena Comfort 5000-5 LCD Art. 1759 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gardena Comfort 5000-5 LCD Art. 1759 in the language / languages: English as an attachment in your email.

The manual is 3.09 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gardena Comfort 5000-5 LCD Art. 1759

Gardena Comfort 5000-5 LCD Art. 1759 User Manual - English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info