584202
6
Zoom out
Zoom in
Previous page
1/17
Next page
min.
1 m
5
1
z
6. Switching on pump 5000/5; 6000/6 inox:
Lift and hold the delivery hose
5
at least 1
m vertically above the pump, insert the
power plug, press the On/Off button
ß
8a
(the LED shines green) and wait until the
pump has primed.
LED
If the pump does not deliver within
approx. 20 seconds, the LED flashes
orange.
If the pump does not deliver: 5000/5
within approx. 5 minutes / 6000/6 inox
within approx. 6 minutes, the LED shines
red and the pump switches off auto-
matically (see “7. Trouble- Shooting”).
v If the pump does not automatically
switch off then manually switch the
pump off and check the hose for
leaks.
The specified maximum self-priming suction height of 8 m is
reached only if the pump is filled via the filler neck
7
up to the
overflow and if, while doing so and during the self-priming, the
delivery hose
5
is held up sufficiently high to prevent any flow
medium escaping from the pump via the delivery hose
5
.
Special mode: Additional electrical switching devices (e. g. remote control sys-
tems, pressure switches) can be used only in the special mode.
Activating the special mode:
1. When switching on, press the On/Off button
ß
8a
for 8 seconds.
During the first 5 seconds, the green LED is illuminated;
then the LED blinks for 3 seconds.
2. When the green LED illuminates again after 8 seconds,
let go of the On/Off button
ß
8a
.
Deactivating the special mode:
1. Plug the mains plug into an energised mains socket.
The pump starts of its own accord.
2. Press the On/Off button
ß
8a
. The pump switches off.
3. When switching on, keep the On/Off button
ß
8a
depressed for
8seconds until the green LED no longer flashes.
safe-pump-function:
The safe-pump function uses the LED status display to alert the
user that there is no water flow. In addition, it acts as Dry-Run-
ning Safety, guarding against pump damage if the delivery side
is closed too long (e.g. closed valves) or if the water supply fails
(e. g. empty cistern).
LED flashes green: Normal operation
LED flashes orange: No water flow for at least 20 seconds
LED shines red: No water flow for at least 5 minutes
(pump has switched off automatically)
LED flashes red: Alarm! Pump was started 3 times within
20 min. without water flow. (Pump can
no longer be started for 5 min. to allow
cooling, after which the LED shines red)
17
GB
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gardena 4000-5 - 1732 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gardena 4000-5 - 1732 in the language / languages: English as an attachment in your email.

The manual is 3,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gardena 4000-5 - 1732

Gardena 4000-5 - 1732 User Manual - German - 18 pages

Gardena 4000-5 - 1732 User Manual - Dutch - 17 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info