Manual operation:
Only for 10000 SL Inox:
Flat suction /
Normal operation
Adjusting the Cut-in and Cut-out Height:
The maximum cut-in height and minimum cut-out height (see
8. Technical Data) can be adjusted.
vPress the cable of the float switch 5into an opening in the float
switch lock 3.
Do not select a cable length that is too long or short to ensure
that the float switch can turn on and off properly.
•The higher the opening of the float switch lock 3, the higher
the cut-in and cut-out height.
•The shorter the length of cable between the float switch 5
and the float switch lock 3, the lower the cut-in height and the
higher the cut-out height.
The cable length between the float switch 5and the float switch
lock 3must always be at least 10 cm.
The pump remains in constant operation because the float switch
is bypassed.
1. Push the float switch 5onto the float switch lock 3with the
cable downward.
2. Stand the pump on a firm surface
– or –
use a rope attached through the bore hole in the carrying
handle 2to immerse the pump in a well or shaft.
3. Plug the power cable 1into a mains socket.
The residual water height (approx. 1 mm for 10000 SL Inox /
40 mm for 18000 SP Inox) is only reached during manual opera-
tion since the float switch turns off the pump during automatic
operation before this water level is reached.
VIf the water height is lower than 3.5 cm, fill the pump
before operation over the universal fitting 7with water.
Flat suction: Normal operation:
v
Turn the 3 swivel feet
8v
Turn the 3 swivel feet
8
180°
to 1 mm.
180°
to 5 mm.
Flat suction up to 1 mm. Flat suction up to 5 mm.
The residual water level of approx. 1 mm is only reached during
flat suction in the manual operation mode. If the water level is
lower than 25 mm, you can accelerate flat suction by switching
the pump off and on 2 to 3 times.