Becquerel < > µSv/h
Conversion of Becquerel (activity) into µSv/h (dose rate)
The relationship between Becquerel (activity, i.e. the measure of the decay in the atom) and micro-
sievert per hour (dose rate, i.e. the measure of the radiation at the device):
The values apply to a point source at a distance of 1m from the device
Cs-137 at a distance of 1m with shield open
1 GBq 86 µSv/h 100 µSv/h 1.17 GBq
100 MBq 8.6 µSv/h 10 µSv/h 117 MBq
10 MBq 0.86 µSv/h 1 µSv/h 11.7 MBq
Cs-137 at a distance of 1m with shield closed
1 GBq 81 µSv/h 100 µSv/h 1.24 GBq
100 MBq 8,1 µSv/h 10 µSv/h 124 MBq
10 MBq 0.81 µSv/h 1 µSv/h 12.4 MBq
Co-60 at a distance of 1m with shield open
1 GBq 372 µSv/h 100 µSv/h 0.27 GBq
100 MBq 37.2 µSv/h 10 µSv/h 27 MBq
10 MBq 3.72 µSv/h 1 µSv/h 2,7 MBq
Co-60 at a distance of 1m with shield closed
1 GBq 339 µSv/h 100 µSv/h 0.30 GBq
100 MBq 33.9 µSv/h 10 µSv/h 30 MBq
10 MBq 3.39 µSv/h 1 µSv/h 3.0 MBq
Tc-99m at a distance of 1m with the shield open
1 GBq 13 µSv/h 100 µSv/h 7.96 GBq
100 MBq 1.3 µSv/h 10 µSv/h 796 MBq
10 MBq 0.13 µSv/h 1 µSv/h 79.6 MBq
Tc-99m at a distance of 1m with the shield closed
Measurement not possible, dose rate too low
20
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gamma Scout Radiation Detector at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gamma Scout Radiation Detector in the language / languages: English as an attachment in your email.

The manual is 2,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gamma Scout Radiation Detector

Gamma Scout Radiation Detector User Manual - German - 26 pages

Gamma Scout Radiation Detector User Manual - Dutch - 13 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info