Functions and Features (all models)
Easy Reading: In measuring mode ( button), the display shows the current radiation
measurement reading every 2 sec. The display also temporarily shows the average H of the last
day (24h, 12 am to 12 am).
Large Scale: GAMMA-SCOUT
®
is calibrated to measure across a wide scale
(0.01 up to 5,000.00 µSv/h).
Tested Calibration: Each GAMMA-SCOUT
®
radiation meter is subjected to a nal test. This test is
supervised by the Institute of Radiation Protection; a state university for applied technology.
The tested device must be within a condence interval of 5% against a master, which in turn,
is adjusted to a gauged reference Cs-137 emitter.
Dose Rate and Dose: GAMMA-SCOUT
®
can be used as a dose meter (cumulative radiation).
Flexible display: The dose rate may be displayed in sievert or Rem.
Energy-Saving Constant Operation: The GAMMA-SCOUT
®
monitors radiation day and night and
logs data for later download. Due to sophisticated electronics, its battery lasts for years.
The “RECHARGEABLE” model works with a rechargeable battery.
Data Storage: GAMMA-SCOUT
®
stores all registered pulses in its internal memory and keeps
them ready for you to use when desired. 32,000 readings: For constant monitoring, storage of
environmental data is set at an interval of one value per week, which equates to
600 years of memory capacity. The user can set smaller intervals (page 14), which lls
the memory capacity sooner. See below for deletion options.
Certification: GAMMA-SCOUT
®
meets all European CE standards as well as the
American “FCC 15 standard”. GAMMA-SCOUT
®
may be carried on aircraft.
GAMMA-SCOUT
®
w/ALERT (basic functions plus alert and ticker)
Dose Rate Threshold: This model features an acoustic alert when radiation level exceeds a user
programmed threshold.
Threshold for (cumulative) Dose: GAMMA-SCOUT
®
w/ALERT offers an acoustic alarm when a
user-programmed threshold for cumulative dose is exceeded.
Ticker: The user can set an acoustic ticker which activates with each gamma pulse detected.
To save battery resources, the signal shuts down after ten minutes and must be restarted.
On devices with rechargeable batteries (see GAMMA-SCOUT
®
RECHARGEABLE) the ticker will
not shut down.
GAMMA-SCOUT
®
ONLINE / REAL TIME (with the functions of the ALERT-model)
Used in Measurement Stations: GAMMA-SCOUT
®
sends detected pulses in real time and at specic
time intervals, adjustable within certain limits, via USB port to the connected PC.
GAMMA-SCOUT
®
RECHARGEABLE (with the functions of the ALERT-model)
Rechargeable power supply, charged via USB (power supply unit or PC).
R
Summary
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gamma Scout Radiation Detector at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gamma Scout Radiation Detector in the language / languages: English as an attachment in your email.

The manual is 2,8 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gamma Scout Radiation Detector

Gamma Scout Radiation Detector User Manual - German - 26 pages

Gamma Scout Radiation Detector User Manual - Dutch - 13 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info