ENGLISH
7.7 ALARM CONDITION
BOILER (FILLING) LEVEL TIME
OUT
This alarm condition occurs whenever the
water level is too low or the level probe
remains uncovered. In such a case the
keyboard leds flash and an alarm message
appears on the display.
The filling stage is automatically engaged
and to cancel the alarm conditions switch
the machine off and then on again.
Lack of volumetric counter impulses
On starting a volumetric control coffee cycle,
the correct function of the volumetric counter
is checked by the reading of the number of
impulses sent by the same to the micro-
controller.
Should no impulses by recorded for a period
exceeding 5 seconds the LED relative to the
selected measure begins flashing (ie. the
led relative to key T4).
After one minute in which no impulses are
recorded (volumetric counter time out), the
measure underway is automatically
stopped.
T4
37


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gaggia E90 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gaggia E90 in the language / languages: English as an attachment in your email.

The manual is 4,35 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info