Technical data (gas)
Burners: Normal burner
Full burning 2.0 kW
Low burning 0.165 kW
Large burner
Full burning 4.0 kW
Low burning 0.165 kW
Wok burner
Full burning 5.0 kW
Low burning 0.3 kW
Total output 17.0 kW
Gas connection: R 1/2’’ union nut for R 1/2’’
bracket to DIN 1999, conical-cylindrical
Technical data (electrical)
Rated consumption
15 W
Voltage AC 220-240 V
Frequency 50-60 Hz
Technical modifications reserved.
11. Technical Data /Nozzle Table
Countries AT BE CH CZ DE BE CH CZ DK AT CH DE
DE DK ES FI ES FI FR GB
FR GB GR HU GR HU IE IS
IE IS IT LU NL IT LU NO PL
PL PT RU SE PT RU
Gas family Natural gas Natural gas LPG/Propane LPG/Prop.
Gas type H / E / L (G 20/25) LL (G 25) 3 + (G30/31) (G30/31)
Pressure 20/25 mbar 20 mbar 28-30/37 mbar 50 mbar
Nozzle, full burn, outer 1.55 1.70 B 1.00 0.87
Nozzle, low burn, outer 0.73 0.81 0.51 0.45
Nozzle, full burn, inner 0.58 0.63 0.37 0.33
Nozzle, low burn, inner 0.45 0.51 0.31 0.25
Air gap adjustm. outer [mm] 0 00 0
Air gap adjustm. inner [mm] * ** *
Total output 17 kW 17 kW 17 kW 17 kW
Total consumption 1.70 m
3
/h 1.87 m
3
/h 1240 g/h 1240 g/h
* open, fixed
Nozzle table wok burner
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gaggenau KG 491 210 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gaggenau KG 491 210 in the language / languages: English as an attachment in your email.

The manual is 1,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gaggenau KG 491 210

Gaggenau KG 491 210 User Manual - German - 32 pages

Gaggenau KG 491 210 User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info