3. Operating Principle
The gas hob features two normal burners,
two large burners and a Wok burner.
The appliance features one-hand operation, flame
detection and automatic re-ignition. The ignition is
activated when the control knob is turned.
Should the flame go out during operation, the
appliance will automatically re-ignite the burner.
During a disturbance, the appliance will cut off the
gas supply as a safety measure, to prevent
unburned gas escaping.
The flame setting is infinitely variable between high
and low.
The total rated thermal load amounts to:
17.0 kW referred to H
s
* (gross calorific value)
15.3 kW referred to H
i
(calorific value)
The specified rated load is defined by installation
of the fixed nozzles.
The gas hob is converted to a different gas
type by nozzle replacement (full and low-burning
nozzles) (see nozzle table on page 17-19).
Off
High
Low
8


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gaggenau KG 491 210 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gaggenau KG 491 210 in the language / languages: English as an attachment in your email.

The manual is 1,87 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gaggenau KG 491 210

Gaggenau KG 491 210 User Manual - German - 32 pages

Gaggenau KG 491 210 User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info