Nozzle Replacement
Changing over to a different gas type
Only authorised specialists are permitted to
change over to a different gas type.
The nozzles needed for the gas type to be set
are available as a conversion kit. Please specify the
appliance type and the required gas type. The
nozzles can be changed on the installed appliance.
Loads for all gases
For all gas types and pressures, the rated load
is achieved by installing the high and low setting
nozzles for the required gas type (see nozzle
table).
Replacing the low setting nozzles
• Switch off the power at fuse point and close the
gas supply!
• Detach pod grids, burner rings, burner head
covers and burner heads.
• Pull off control knobs. Undo trough securing nuts
(three 7 mm nuts on each burner) and carefully
detach the trough.
• Turn the black plastic part so that the recess is
above the nozzle. Screw out nozzle and take
nozzle out with small pliers.
• Replace both low setting nozzles on the gas taps
according to the new gas type and as detailed in
the low setting nozzle table. Fully screw in the
new low setting nozzles.
Important: be careful not to damage the O-ring.
23
See table on page 17-19
for details of nozzle settings.
outer low
setting nozzle
inner low
setting
nozzle
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gaggenau KG 291-220 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gaggenau KG 291-220 in the language / languages: English as an attachment in your email.

The manual is 1,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gaggenau KG 291-220

Gaggenau KG 291-220 User Manual - German - 32 pages

Gaggenau KG 291-220 User Manual - Dutch - 32 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info