What to do in the event of a fault
Faults often have simple explanations. Before you call
our after-sales service, please read the information in
the table below.
Note: Any repair work must only be carried out by
qualified experts. Incorrect repairs to your appliance
may present considerable risks for the user.
Fault Error Causes Possible remedy
The symbol will appear
after a few seconds.
The vacuum cannot be
created properly.
The glass lid has not been closed
properly.
Open and close the glass lid again.
When doing so, lightly press on the
glass lid for the first few seconds.
The seal on the glass lid is not fitted
properly or is defective.
Check the seal.
The seal on the glass lid has
deformed.
Gently press the seal to straighten it
out.
The lid on the external vacuum-seal-
ing container has not been closed
properly.
Check the position of the vacuum-
sealing lid. Only use suitable vac-
uum-sealing containers.
The external vacuum-sealing con-
nection is not positioned correctly
on the vacuum-sealing chamber's
air outlet.
Check the position of the external
vacuum-sealing connection.
The symbol will appear
after the pump has been
running for 2 minutes.
It is taking too long to cre-
ate a vacuum. Your
selected vacuum-sealing
level cannot be reached.
As the temperature rises, liquids
begin to boil. At this point, the pro-
cess of creating a vacuum stops.
Only vacuum-seal cold liquids.
If the vacuum-sealing chamber is
wet, wipe it dry.
Heat-seal the vacuum-sealing bag
early if large bubbles form.
Select a lower vacuum-sealing level.
The vacuum-sealing pro-
cess will not start. The
² symbol does not
appear even though the lid
is closed.
The appliance is not
detecting the lid.
The door switch on the glass lid is
missing or is not being detected by
the appliance.
Call the after-sales service.
If you try to operate the
appliance several times in
succession, the vacuum-
sealing process seems to
run as normal but the bag
is not heat-sealed.
The thermal switch on the heat-seal-
ing transformer has been triggered.
Allow the appliance to cool for at
least 10 minutes. Then try again.
Allow the appliance to cool for at
least 2 minutes between vacuum-
sealing operations.
The vacuum-sealing pro-
cess is taking longer and
longer.
There is too much moisture in the
pump system.
The appliance monitors the vacuum-
sealing as it progresses. If too much
liquid is retained in the pump oil,
the ¢ symbol will appear. Initiate
drying.
The pump system is extremely hot. Allow the appliance to cool and
then try again.
After the drying proce-
dure, the appliance dis-
plays the ¢ and
symbols.
One drying cycle alone was not suf-
ficient.
Wait until the symbol is no
longer lit up. Then start another dry-
ing cycle.
29


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gaggenau DVP221110 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gaggenau DVP221110 in the language / languages: English, German as an attachment in your email.

The manual is 1,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gaggenau DVP221110

Gaggenau DVP221110 User Manual - Dutch, French, Italian - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info