6.1 Technical data
Appliance dimensions: L 700 x T 510 x H 63,5 mm
Installation dimensions: L 680 x T x 490 x H 55 mm
Total rating: 7.2 kW
6.2 Important notes on installation
–Pay attention to the "Important notes"
(Chapter 1).
The appliance must only be connected by an
authorised specialist, paying attention to the
relevant regulations of the power supply compa-
nies and the regional construction regulations.
– The electrician is responsible for the correct
functioning of the appliance at the time of
installation. He must instruct the user on how
to operate the appliance correctly on the basis
of the Operating Instructions, and the user must
be instructed on how to disconnect the appliance
in an emergency.
If the range is not installed over a built-in cooker,
protection against hazardous contact from
below must be ensured after assembly, e.g. by
installing an intermediate shelf that can only be
detached using a tool.
The distance between the intermediate shelf and
the worktop in which the range is recessed must
be at least 60 mm.
Note: when installing a shelf, observe a distance
of at least 50 mm from the bottom edge of the
housing trough to the shelf or the next
combustible item of furnishing.
If all poles of the appliances cannot be isolated
from the mains by removing an accessible plug
(of a permanent connecting lead), an isolating
device with a contact gap of at least 3 mm must
be installed (e.g. domestic fuse).
No warranty claims can be lodged for any
damage resulting from failure to observe
these instructions.
When the appliance is installed in a base cabi-
net with a width of less than 60 cm, the housing
can lie on the side walls of the cabinet. These
cabinet side panels must be modified so that the
appliance is not in contact with them.
Note: Please note that a distance of 10 mm from
the base cabinet must be observed for safety
reasons.
– The distance from the lower edge of the housing
trough to the next combustible item of furnishing
at the side should be at least 20 mm.
Note: Do not stick the cooking surface onto the
worktop with silicone !
Electrical connection
Rated power consumption:
7.2 kW
The appliance must only be connected by an
authorised specialist.
All corresponding regulations must be observed.
The mains connecting cable must at least
correspond to the type H 05 VV-F.
Pay attention to the data on the rating plate
and connect the PE conductor. Connect the
connecting cable to the mains. The appliance can
be connected with a plug or it can be connected
permanently.
When connecting electrical appliances and
devices in the proximity of cooking surfaces and
ovens, make sure that connecting cables do not
become jammed under the hot oven door or
come into contact with hot cooking surfaces.
This cooker corresponds to heat class Y and
must be installed in a cabinet as detailed in the
sketch (Fig. 7).
This appliance may be installed in kitchen com-
binations made of wood or similar combustible
materials without taking additional measures.
6. Assembly instructions
CK 270-504 FD xxxx
AC 240 V 50/60 Hz 7200 W
30 A
CK 270-104 FD xxxx
AC 230/400 V 3 N / 50/60 Hz 7200 W
3 x 16 A
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gaggenau CK 270-104 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gaggenau CK 270-104 in the language / languages: English as an attachment in your email.

The manual is 0,3 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gaggenau CK 270-104

Gaggenau CK 270-104 User Manual - German - 12 pages

Gaggenau CK 270-104 User Manual - Dutch - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info