en Cleaning and maintenance
Strainer filter
You can clean the strainer filter in the cooking
compartment floor as necessary. When cooking fish or
meat, we recommend cleaning the appliance after each
use.
1Turn the strainer filter anticlockwise and remove it.
2Remove any food remnants from the strainer filter.
3Rinse it out under running water. If it is very dirty,
wash it in the dishwasher.
4Insert the strainer filter and turn it clockwise as far
as it will go.
Never operate the combi-steam oven without the strainer
filter in place.
Cleaning programme
The cleaning programme removes stubborn dirt. A
cleaning cartridge (a) is screwed into the top of the
cooking compartment. The cooking compartment is
cleaned, rinsed and dried fully automatically. The
strainer filter (b) must remain inserted in the cooking
compartment floor while the cleaning programme is in
progress.
Depending on which version of the appliance you have,
the complete cleaning programme takes either 3 hours
20 minutes or 3 hours 45 minutes.
With normal use, we recommend cleaning the appliance
with the cleaning programme four times a year.
Depending on how you use your appliance, more
frequent cleaning may be required.
If there are a lot of food remnants, do not allow them to
burn on. Start the cleaning programme as soon as the
appliance has cooled to 40 °C.
You need special cleaning cartridges for the cleaning
programme. These are available from the after-sales
service or from our online shop (CL S10 040set with
4cleaning cartridges, order number 00311703).
The cleaning cartridges can only be used once and
cannot be refilled. Do not use any other cleaning
products.
Caution!
Risk of damage to the cooking compartment
Use cleaning cartridges for the cleaning programme
only. Never place cleaning cartridges in the cooking
compartment when it is hot or heat them up in the
cooking compartment.
Notes
The cleaning programme cannot be started until the
appliance has cooled down to below 40 °C.
Remove all accessories from the cooking
compartment before you start the cleaning
programme (wire rack, cooking containers, core
temperature probe).
Remove the worst of the food remnants from the
cooking compartment.
The strainer filter must remain inserted in the
cooking compartment floor while the cleaning
programme is in progress. If the strainer filter is
removed before the cleaning programme is started,
the cooking compartment will not be clean at the
end of the programme.
The appliance door remains locked while the
cleaning programme is in progress.
Do not attempt to open the appliance door while the
cleaning programme is in progress. Otherwise,
water may leak out.
The noise from the appliance fan is louder when the
cleaning programme is in progress. This is normal.
Always allow the cleaning programme to run to the
end. The cleaning programme cannot be cancelled.
E
D
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gaggenau BS475102 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gaggenau BS475102 in the language / languages: English as an attachment in your email.

The manual is 2,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gaggenau BS475102

Gaggenau BS475102 User Manual - German - 60 pages

Gaggenau BS475102 User Manual - Dutch - 60 pages

Gaggenau BS475102 User Manual - French - 64 pages

Gaggenau BS475102 Installation Guide - All languages - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info