761916
9
Zoom out
Zoom in
Previous page
1/88
Next page
9
Operating the appliance en
Sensor control
In automatic mode, the sensor in the extractor hood
detects the intensity of the cooking and roasting
odours. Depending on the sensor setting, the fan
automatically switches itself to another fan setting.
Possible sensor settings:
Default sensitivity setting: 3 (fan setting 3)
Lowest sensitivity setting: 1 (fan setting 1)
Highest sensitivity setting: 4 (fan setting Ò)
If the sensor controller responds too strongly or not
enough, it can be changed accordingly:
1Touch and hold the r symbol when the fan is
switched off. The setting is displayed.
2The sensor controller setting can be changed by
touching symbols 1, 2, 3, or Ò.
3Touch and hold the r symbol to confirm.
Saturation display
If the metal grease filters or activated charcoal filter
are/is saturated, the corresponding symbols will flash
once the appliance has been switched off:
Metal grease filters:œ and 1
Activated charcoal filter:œ and 2
Regenerative activated charcoal filter: œ and 3
If you have not yet done so, the metal grease filters
should now be cleaned or the activated charcoal filter
replaced. ~ "Cleaning and maintenance" on page 13
The saturation indicators can be reset while they are
flashing. To do this, press and hold the œ symbol.
If the œ symbol lights up while the appliance is
switched off, you can query which filter is saturated. To
do this, touch the œ symbol. The corresponding
symbols (1, 2, 3) will flash.
Switching over the display for air recirculation mode
For air recirculation mode, the electronic controller
must be switched over accordingly:
The extractor hood must be connected and
switched off.
Touch and hold the œ symbol. Touch the
"2" symbol.Touch and hold the œ symbol to
confirm. This will switch the electronic controller
over to air recirculation mode (filters that cannot be
regenerated).
Touch and hold the œ symbol. Touch the
"3" symbol.Touch and hold the œ symbol to
confirm. This will switch the electronic controller
over to air recirculation mode (filters that can be
regenerated).
Touch and hold the œ symbol again. Touch the
"1" symbol. This will switch the electronic controller
back to air extraction mode.
Press and hold the œ symbol to save.
Indirect LED lighting
The indirect LED lighting can be switched on and off
independently of the fan.
Touch the j symbol.
Setting the brightness
Press and hold the j symbol until the required
brightness is reached.
Lighting
The lighting can be switched on and off independently
of the fan.
Touch the ž symbol.
Setting the brightness
Press and hold the ž symbol until the required
brightness is reached.
Audible signal
Switching on
To go to the settings mode for the signal tone, touch
and hold the # and Ò symbols at the same time for
approximately 3 seconds when the fan is switched off.
Touch the "1" symbol. Touching and holding the # and
Ò symbols again will save the setting. An audible
signal will sound as an acknowledgement.
Switching off
To go to the settings mode for the signal tone, touch
and hold the # and Ò symbols at the same time for
approximately 3 seconds when the fan is switched off.
Touch the "2" symbol. Touching and holding the # and
Ò symbols again will save the setting.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gaggenau AW250192 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gaggenau AW250192 in the language / languages: English, Portuguese, Spanish as an attachment in your email.

The manual is 4,03 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gaggenau AW250192

Gaggenau AW250192 User Manual - German, Dutch, French, Italian - 88 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info