761919
22
Zoom out
Zoom in
Previous page
1/116
Next page
22
Operating the appliance
Note: Switch on the extractor hood when you start
cooking and switch it off again several minutes after you
have finished cooking. This is the most effective way of
removing the kitchen fumes.
Operating the appliance
Control panel
Setting the fan
Switching on
To extend the filter pull-out, press down lightly on the
middle of the handle strip. The fan will start at setting 2.
Press the 1, 2 or 3 button to change the fan strength.
Switching off
Press the # button. Slide the filter pull-out in.
Intensive setting
You can use the intensive setting if there is a large build-
up of odours and fumes/vapours.
1Press the ÿ button.
The fan starts at setting 2.
2Press the Ž button.
The intensive setting is activated.
Note: The intensive setting is a time-limited
maximum setting which can be activated at
any fan setting and in automatic mode. After
approx. 6 minutes, the fan resets to the previously
selected fan setting.
3To end the intensive setting early, press the
ÿ button or the button for another fan setting.
Fan run-on time
If you slide in the filter pull-out, the run-on time will be
activated for as long as the extractor hood is operating.
After approx. 10 minutes, the fan switches off
automatically.
Automatic mode
Switching on the appliance
Press the # button.
The fan starts at setting 2.
Press the < button.
The optimum fan setting 1, 2 or 3 is automatically
set via a sensor.
Switching off the appliance
Press the < or # button to switch off automatic mode.
The fan switches off automatically if the sensor no
longer detects a change in the air quality of the room.
The automatic mode lasts 4 hours at most.
Sensor control
In automatic mode, a sensor in the extractor hood
detects the intensity of the cooking and roasting fumes.
Depending on the setting of the sensor, the fan
automatically switches to another fan setting.
Default sensitivity setting: 2
Lowest sensitivity setting: 1
Highest sensitivity setting: 4
If the sensor control responds too quickly or too slowly,
it can be changed accordingly:
1When the fan is switched off, press the < button
and hold it for approx. 4 seconds. The setting is
displayed.
2Press the 1, 2, 3 or Ž button to change the setting
of the sensor control.
3To confirm the entry, press and hold the < button
for approx. 4 seconds.
Explanation
#Fan on/off
1 Fan speed 1
2 Fan speed 2
3 Fan speed 3
ŽIntensive setting
<Automatic mode
œSaturation indicator
cLight on/off/dimming
Button 1 = Sensitivity 1
Button 2 = Sensitivity 2
Button 3 = Sensitivity 3
Ž Button = Sensitivity 4
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gaggenau AF210162 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gaggenau AF210162 in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 5,36 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gaggenau AF210162

Gaggenau AF210162 Usermanual and installation guide - German - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info