644210
2
Zoom out
Zoom in
Previous page
1/2
Next page
Screen 1
- Sounds Setup To go to the other menu
- SpO2 Alm Hi Set hi levels of oxygen
percentage
- SpO2 Alm Lo Set low levels of oxygen
percentage
- PR Alm Hi Set high levels of pulse
rate
- PR Alm Lo Set low levels of pulse rate
- +/- Switch between going
higher or lower
- Exit To exit the menu
Screen 2
- Alm Setup To go to the other menu
- Alm To switch the alarm on or
off
- Beep To switch the pulse rate
alarm on or off
- Restore To restore back to factory
settings
- Exit To exit the menu
Maintenance:
Cleaning and storage:
Clean the black rubber nger sleeve before
and after using with medicinal alcohol (>
95%).
The exterior part of the tester can be cleaned
using a damp cloth. The FPO-10 is not water-
proof, so DO NOT immerse in water.
Keep the pulse Oximeter out of the reach of
children, and preferably inside the included
case in a dry place.
See the technical specications regarding
storage conditions.
Batteries:
The batteries can power the unit for 24 hours
continuously.
If the device will not be used for a long period
(> 2 months), remove the batteries. Doing so
prevent any possible damage from leaking
batteries.
Replace the batteries when the battery indica-
tor shows that the batteries are running low.
Always place two identical batteries, type
alkaline, size AAA.
Rechargeable batteries should not be used
due to their lower voltage.
Environment:
Should the device need to be discarded, hand
it over to your supplier. They will dispose of it
in an environmentally friendly manner.
Empty batteries can be returned to the sup-
plier or disposed of in an environmentally-
friendly manner according to your local regu-
lations. Do not dispose of used batteries with
your normal household waste.
Technical:
Calibration:
The FPO-10 does not need to be calibrated.
Specications:
Display: Colour, type OLED
Pulse rate:
Range: 25bpm ~ 250bpm
Resolution: 1bpm
Accuracy: 2bpm
Strength: bar chart
(bpm = beats per minute)
SpO2:
Range: 0% -100%
Resolution: 1%
Accuracy: 70% -100%: ± 2%
0% -69%: unspecied
Batteries: 2x AAA, 1.5V, Alkaline
Consumption: 30mA (nominal)
Battery life: 24 hours continuous use
Dimensions, weight:
64 x 35 x 34mm / 65 grams (incl. batt)
Surroundings:
Operating temperature: 5°C ~ 40°C
Storage temperature: -10°C ~ 50°C
Operating humidity: 15% ~ 80%
Storage Humidity: 10% ~ 93%
Declaration of Conformity:
The FPO-10 conforms to the EMC standard
IEC60601-1-2.
The materials of the FPO-10 for which the
user will touch complies with the standards
ISO 10993-1, -5 and -10 (does not contain
dangerous toxins and causes no reaction to
skin tissues).
Service:
24 months Warranty ● FPO-10 does not con-
tain any service components/accessories ●
maintenance only through the service depart-
ment of Fysic.
: Wellkang Ltd, Suite B, 29 Harley Street,
London, W1G9QR, U.K.
: Shenzhen Jumper Medical Equipment Co.,
Limited, 5th Floor Building No. 34, Baoyuan
Industrial Zone, Xixiang Street, Baoan District,
Shenzhen 518102, P.R. China Public E-mail:
info@jumper-medical.com Tel: +86-755-
26692192, 26696279 Fax: +86-755-26852025
v1.00482
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fysic FPO 10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fysic FPO 10 in the language / languages: English as an attachment in your email.

The manual is 0,45 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fysic FPO 10

Fysic FPO 10 User Manual - German - 2 pages

Fysic FPO 10 User Manual - Dutch - 2 pages

Fysic FPO 10 User Manual - French - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info