747919
65
Zoom out
Zoom in
Previous page
1/178
Next page
65
System Menu
+(/,&237(5
$,53/$1(*/,'(5
S.BUS Servo Description of function of each parameter
*There are functions which can be used according to the kind of servo, and an impossible function.
• ID
Displays the ID of the servo whose parameters are to be read. It cannot be changed.
• Channel
Channel of the
S.BUS
system assigned to the servo. Always assign a channel before use.
• Reverse
The direction in which the servo rotates can be changed.
• Servo type
Normal: Normal operation mode
Retract: Landing gear retract mode. When a load is applied to the servo for 30 seconds without any channel
operation performed from the transmitter, the current consumption is suppressed by widening the dead
band to 40°. When channel operation is performed from the transmitter, or the servo is moved outside the
expanded dead band by an outside force, dead band expansion is reset and returns to the original operation.
O.L.P. : This is the Over Load Protection mode. When a servo horn has been locked for more than 5 seconds
by a load, the servo output turns off to protect the servo.
* The normal mode and retract mode are applicable only to the S3171SB, S9071SB, S9072SB, S9074SB, and
S9075SB
• Soft Start
Restricts operation in the specified direction the instant the power is turned on. By using this setting, the first
initial movement when the power is turned on slowly moves the servo to the specified position.
• Stop Mode
The state of the servo when the servo input signal is lost can be specified. The "Hold" mode setting holds the
servo in its last commanded position even if using AM or FM system.
• Smoother
This function changes smoothness of the servo operation relative to stick movement changes. Smooth setting
is used for normal flight. Select the "OFF" mode when quick operation is necessary such as 3D.
• Neutral Offset
The neutral position can be changed. When the neutral offset is large value, the servo's range of travel is
restricted on one side.
• Speed Control
Speeds can be matched by specifying the operating speed. The speed of multiple servos can be matched
without being affected by motor fluctuations. This is effective for load torques below the maximum torque.
However, note that the maximum speed will not exceed what the servo is capable of even if the servos
operating voltage is increased.
• Dead band
The dead band angle at stopping can be specified.
[Relationship between dead band set value and servo operation]
Small
ĺ
Dead band angle is small and the servo is immediately operated by a small signal change.
Large
ĺ
Dead band angle is large and the servo does not operate at small signal changes.
(Note) If the dead band angle is too small, the servo will operate continuously and the current consumption will
increase and the life of the servo will be shortened.
• Travel Adjust
The left and right travels centered about the neutral position can be set independently.
65


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Futaba T-18MZ-WC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Futaba T-18MZ-WC in the language / languages: English as an attachment in your email.

The manual is 8,9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info