747921
162
Zoom out
Zoom in
Previous page
1/174
Next page
162
<Functions of Model Menu (Helicopter Functions)>
ŏ Select the function name
and return to the Model
menu by touching the
RTN button or pushing the
HOME/EXIT button.
<SensorTouch™>
RETURN
GOVERNOR mixing
:KHQXVLQJD)XWDED*9*<&*<
JRYHUQRUWKLVIXQFWLRQLVXVHGWRVZLWFKWKH530
of the helicopter's rotor head. The rotor head speed
FDQEHVZLWFKHGZLWKHDFKFRQGLWLRQRUWKHVZLWFK
7KHJRYHUQRULVXVHGE\FRQQHFWLQJWKHJRYHUQRUVSHHG
VHWWLQJFKDQQHOWR&+LQLWLDOVHWWLQJ
*When using an independent governor [ON]/[OFF] switch,
connect the AUX([ON]/[OFF]) connector of the governor to
&+DQGVHWWKHVZLWFKWR&+*RYHUQRUDWWKH)XQFWLRQ
menu of the Linkage Menu.
Note: Always set (Control) and (Trim) to [--]
for [Governor] of the Function menu of the
Linkage menu.
ŏ Select [GOVERNOR] at the Model menu and access
the setup screen shown below by touching the RTN
button.
Scrolling
ŏ Moving cursor
ŏ Selecting mode
ŏ Adjusting value
ŏ To next page
(Currently selected condition name)
ŏUnit display selection:
[]/[rpm]
ŏSetup screen selection
ŏACT/INH: INH (initial setting)
ŏFine tuning VR settings
ŏRPM adjustment
ŏCondition/Switch selection
Setting method
Ɣ$FWLYDWHWKHPL[LQJ
When using this function, move the cursor to
the [INH] item and touch the RTN button to
switch to the data input mode.
Select the ACT mode by scrolling the touch
sensor.
7KHGLVSOD\EOLQNV
Touch the RTN button to activate the mixing
and return to the cursor mode. (ON is
displayed.)
When the Governor is changed from the
default inhibited (INH) state to the active
(ACT) state, the endpoint menu will be
displayed and it is possible to utilize the
endpoints for this given condition.
*When the function is set ON/OFF at the governor setup
screen, the governor rpm setting channel end point servo
travel and limit point are now initialized.
:KHQFKDQJHGIURP,1+WR$&721WKHVHUYRWUDYHOLV
initialized to 100 and the limit point is initialized to 155.
:KHQRSHUDWLRQLVFKDQJHGWR,1+DWDOOFRQGLWLRQVWKH
servo travel is initialized to 100 and the limit point is
initialized to 135.
Use the SensorTouch to scroll to either YES
(incorporate the default endpoints) or NO
(endpoints are not utilized. Press the Return
(RTN) button to conÀrm the selection made.
Ɣ530DGMXVWPHQW
Move the cursor to the rate item and touch
the RTN button to switch to the data input
mode.
Adjust the rpm by scrolling the touch sensor.
Initial value: 50 (1500rpm)
Adjustment range: OFF, 0~110 (OFF,
700~3500rpm)
:KHQWKH571EXWWRQLVWRXFKHGIRURQHVHFRQGWKH
sensitivity is reset to the initial value.)
Touch the RTN button to return to the cursor
mode.
Ɣ8QLWGLSOD\VHOHFWLRQ
Move the cursor to the UNIT item and touch
the RTN button to switch to the data input
mode. Select the unit by scrolling the touch
sensor.
Touch the RTN button to change the
operation mode and return to the cursor
mode.
162


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Futaba FX22 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Futaba FX22 in the language / languages: English as an attachment in your email.

The manual is 4,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info