<Functions of Model Menu (Helicopter Functions)>
ŏ Select the function name
and return to the Model
menu by touching the
RTN button or pushing the
HOME/EXIT button.
<SensorTouch™>
RETURN
PIT to RUD mixing (Revolution mixing)
Use this mix when you want to suppress the
UHDFWLRQWRUTXHJHQHUDWHGE\PDLQURWRUSLWFKDQG
speed changes during pitch operation. Adjust so
that the nose does not move in the rudder direction.
<Normal condition mixing curve>
The mixing curve rate should be started
using smaller values.
For a rotor with a clockwise operation
direction, when pitch was input at the plus
side, set these parameters so that mixing
is in the clockwise direction. First, trim at
hovering and then adjust the neutral
position.
1. Adjustment between slow and hovering
Repeatedly hover from take off and land
at a constant rate matched to your own
rhythm. Then adjust the pitch so that the
nose of the helicopter remains steady
when the throttle is raised and lowered.
2. Throttle high side (climbing and diving from
hovering)
Repeat climbing and diving from hovering
at a constant rate matched to your own
rhythm and adjust the pitch so that the nose
does not deflect when the throttle is raised
and lowered.
Note: When a GY Series or other heading hold
gyro is used, since correction is performed by
the gyro, this mix is not utilized. If this function
is used when the gyro operation mode is the
AVCS mode, the neutral position will change.
<Idle up condition mixing curve>
Set the mixing rate so that the rudder direction
at high-speed Áight is straight ahead. Adjust for
each condition used.
ŏ Select [PIT to RUD] at the Model menu and access
the setup screen shown below by touching the
RTN button.
(Currently selected condition name)
Scrolling
ŏ Moving cursor
ŏ Selecting mode
ŏ Adjusting value
ŏ To next page
Setting method
Ɣ$FWLYDWHWKHPL[LQJ
When using this function, move the cursor to
the [ACT] item and touch the RTN button to
switch to the data input mode.
Select the ACT mode by scrolling the touch
sensor.
7KHGLVSOD\EOLQNV
Touch the RTN button to activate the mixing
and return to the cursor mode. (ON is
displayed.)
ƔSRLQWFXUYHVHWWLQJ
Move the cursor to the curve rate setting
item you want to adjust and touch the RTN
button to switch to the data input mode.
Adjust the rate by scrolling the touch sensor.
Initial value: P1~P5: 0
Adjustment range: -100~100
:KHQWKH571EXWWRQLVWRXFKHGIRURQHVHFRQGWKHUDWHLV
reset to the initial value.)
Touch the RTN button to end the adjustment
and return to the cursor mode.
Repeat this procedure for each point.
Ɣ3LWFKFXUYHFRS\IXQFWLRQ
Move the cursor to COPY item and touch the
RTN button to switch to the data input mode.
Select the copy destination condition by
scrolling the touch sensor and touch the RTN
button. Select the [YES] and touch the RTN
button.
158


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Futaba FX22 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Futaba FX22 in the language / languages: English as an attachment in your email.

The manual is 4,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email