GOVERNOR BASIC
MAP. 2
/
2
(7) Governor on/off switch
[default: Inhibit]
This parameter allows turning of the governor
on and off via a transmitter switch. Pushing the
SET (Data+) key activates the function. The on/
off direction is changed by pushing the SET key
again. The function is inhibited by pushing the
RSET (Data-) key.
(8) Servo limit point setting
Servo limit point setting defines the overall trav-
el range for the throttle servo. It is fundamental
for governor operation and must be set prior to
other functions. Servo limits must also be reset
when the throttle linkage or trim are changed.
For this setting, idling position is set first, then
high position as guided by the display. Push
the data + or – key to memorize. “*Write*” is
displayed when the setting is completed. “Error”
is displayed when the setting position is out of
range (too little servo travel between low and
high throttle positions).
WARNING
When using the CGY750 for the first time, or
when making changes in the throw of a servo
and its linkage, always perform the limit setting
operation.
(9) Revolution sensor testing
It tests the output level of the revolution sensor. Turn the engine by hand, and check the output
level. The display indicates the current level on left side numbers, maximum level on right side
numbers. The output level needs to be more than 60 % for correct governor operation.
(10) Sensor type
Select the type of governor sensor:
-Nitro (BPS-1 backplate; Magnet Type)
-1:1 Magnet “1:1 Mag” (Magnet type applied to helicopter part that turns at the same RPM as the
main rotor)
-HPoleEP: For Electric motors 8 poles and above
-LPoleEP: For electric motors 6 poles.
(11) Governor gain
Governor Gain. Too low of number the RPM will fluctuate with collective pitch and cyclic changes.
Too high of gain the RPM will oscillate and possibly surge during flight.
(12) Low limit RPM
Low RPM Limit sets the minimum amount of throttle that the governor will command during an
over-speed situation. Too low of value the engine could shut off or not recover power quickly
enough during the next collective movement. If the value is set too high, the governor will not con-
trol overspeed with the rotor head is unloaded.
Use:
LLmt Lrpm: For RPMS of 700-1700
LLmt Hrpm: For RPMS of 1701-4000
Rrturn to GOVERNOR MAP. 1/2
*It does not display, when Opr.mode is
Gyro+THR, and when SWASH-type is
H4-00/H4-45.
*It does not display, when Opr.
mode is Gyro+THR, and when
SWASH-type is H4-00/H4-45.
Push
DATA
+/– key
Push
DATA
+/– key
Push
MODE
+/– key
Push
DATA
+/– key
When CondMenu is ON, this
changes into CondMenu.
When CondMenu is ON, this
changes into CondMenu.
When CondMenu is ON, this
changes into CondMenu.
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Futaba CGY750 V 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Futaba CGY750 V 2.0 in the language / languages: English as an attachment in your email.

The manual is 1,12 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info